Condenser
B
=
Stopper strip with profiled joint
H
=
Ventilation height
Fig. 2
Installation steps
1. Cut out a rectangle (L300:width 490mm, height 249mm, L500:width 451mm,
height 341mm) in the external wall and install the frame (
1
) with screws.
2. Position the ventilation grid (
2
) into the frame (
1
) and fasten it with the
locking sliders (
3
).
Please note, that this ventilation grid does not have the parts for the
exhaust conduction.
The
upper
ventilation grid should be positioned as high as possible above
condenser (A).
The
lower
ventilation grid should be flush with the floor of the vehicle.
Minimum ventilation height (H) = ca.
1400mm − 1500mm