Make sure no combustible objects are stored or installed near the air outlet.
A distance of at least 50 cm should be kept.
•
Make sure that there are no objects within the vehicle which could obstruct
the attachment of the air outlet unit or the cooled air from flowing through the
swivelling air distribution nozzles.
•
For safety reasons, note the location of existing wiring harnesses, wires and
other components within the installation area, in particular those which are
not visible, when installing the roof air conditioner (when drilling or screwing
etc.).
Note on electrical system
•
The appliance shall be installed in accordance with national wiring regula-
tions.
•
Only a qualified electrician should connect the roof air conditioner to the
electrical power.
•
Check that the voltage specification on the type plate is the same as that of
the power supply.
•
Do not lay cables which are loose or bent next to electrically conductive
material (metal).
•
Install an all-pole switch with a contact opening width of at least 3 mm on the
installation side.
•
Ensure that the mains voltage supply has a residual current circuit breaker.
•
Make sure that the grounding cable of the air conditioner is connected to the
vehicle‘s grounding system.
There are two ways of installing the roof air conditioner:
•
Making a new opening (chapter “Making a new opening” on page 11). In this
case the opening must be reinforced by an appropriate frame.
•
Using an existing opening in the vehicle such as a roof hatch or replacing an
old air conditioner (chapter “Installing in an existing opening” on page 12).
IBIS4-A4--I.book Seite 10 Mittwoch, 13. März 2019 9:43 21