![Dometic FreshWell 2000 Скачать руководство пользователя страница 26](http://html.mh-extra.com/html/dometic/freshwell-2000/freshwell-2000_installation-manual_2518269026.webp)
EN
Troubleshooting
Dometic FreshWell 2000
24
8
Troubleshooting
Problem
Cause
Remedy
No cooling
capacity
The under-bench air conditioner is
not set to cooling.
➤
Set the under-bench air condi-
tioner to cooling.
The ambient temperature is above
43 °C.
The under-bench air conditioner is
only designed for ambient temper-
atures of up to 43 °C.
The temperature set is higher that the
room temperature.
➤
Select a lower temperature.
The ambient temperature is below
16 °C.
The under-bench air conditioner is
only designed for ambient temper-
atures above 16 °C.
The thermal protection is defective.
➤
Contact an authorised work-
shop.
The compressor is damaged.
The refrigerating agent filling is
insufficient.
The heat exchange coils are polluted.
The external blower is defective.
Low air output
The air filter is obstructed.
➤
Clean the air filter.
The heat exchange coils are polluted.
➤
Contact an authorised work-
shop.
The internal blower is defective.
Water enters the
vehicle
The condensation water drainage
openings are clogged up.
➤
Clean the drainage openings
for condensation water.
The seals are damaged.
➤
Contact an authorised work-
shop.
Under-bench air
conditioner does
not switch on.
No supply voltage (230 V
w
) con-
nected.
➤
Check the power supply.
The voltage is too low (under
200 V
w
).
The voltage converter is defective.
➤
Contact an authorised work-
shop.
The defective thermal protection is
defective.
The condenser fan is damaged.
The compressor is damaged.
The electrical fuse of the power
supply is too low.
➤
Check the electrical fuse of the
power supply.