Making openings
See fig.
3
➤
Mark the position and size of the openings using the template included in
the packaging (
A
and
B
).
See fig.
4
➤
Drill out the corners (
A
).
➤
Carefully cut out the opening on the roof using a keyhole saw or a similar
tool (
B
).
Make sure no electrical power cables are damaged.
➤
Drill out a condensation water drainage opening with a diameter of 32 mm
(
C
).
See fig.
5
➤
Mark the position of the angle sections (
A
) or the fastening brackets (
B
)
according to the way you‘ve chosen to fix the under-bench air conditioner.
7.3
Fastening with the angle section
See fig.
6
➤
Fasten the under-bench air conditioner with the two angle sections an
three fastening screw for each as shown.
7.4
Installing in a roof hatch opening already provided
See fig.
7
➤
Fasten the four fastening brackets (
A
).
➤
Pull the belts through the fastening brackets (
B
).
➤
Fasten the under-bench air conditioner with the belts (
C
).
7.5
Installing the receiver
See fig.
8
➤
Drill an opening of 50 mm into the wall.
See fig.
9
➤
Lay the cable through the hole to the under-bench air conditioner.
➤
Fasten the receiver as shown.