![Dometic FreshJet Chillout ADB 9102900232 Скачать руководство пользователя страница 41](http://html.mh-extra.com/html/dometic/freshjet-chillout-adb-9102900232/freshjet-chillout-adb-9102900232_installation-manual_2518255041.webp)
EN
Dometic FreshJet
Installation
37
See fig.
c
A
➤
Tighten the screws using a torque spanner and a fastening torque of
2.5 Nm.
Electrical connection
The complete circuit diagram can be found in fig.
i
:
Keys for fig.
j
:
See fig.
d
230 V
w
cable
➤
Connect the roof air conditioner with the 230 V
w
voltage supply.
Connect the cables (
1
) to a cable connector (
2
).
NOTICE! Risk of damage
Tighten to the specified torque.
Item
Description
1
230 V
w
mains
2
Compressor
3
Fan condenser
4
Fan condenser (FreshJet 2600, FreshJet 3200 only)
5
Fan evaporator
6
Battery
7
Remote socket
8
Temperature sensor
9
Heating (FreshJet 1700, item no. 9105305736 and
FreshJet 2200, item no. 9105305738, 9105305740 only)
10
Heat Pump (FreshJet 2600, FreshJet 3200 only)
11
Soft Start (FreshJet 2200, item no. 9105305738, FreshJet 2600,
FreshJet 3200 only)
Item
Description
1
Remote light switch
2
Air diffuser