EN
Installation
Dometic FreshJet
34
Note on electrical system
Only a qualified electrician should connect the roof air conditioner to the
electrical power.
Check that the voltage specification on the type plate is the same as that
of the power supply.
If the lighting should also be switched on without a 230 V voltage supply,
make sure that there is a 12 V
g
power supply line from the battery to the
roof air conditioner.
Do not lay the 230 V mains cable and the 12/24 V
g
cable together in the
same cable duct.
Do not lay cables which are loose or bent next to electrically conductive
material (metal).
Install an all-pole switch with a contact opening width of at least 3 mm on
the installation side.
There are two ways of installing the roof air conditioner:
Making a new opening (chapter “Making a new opening” on page 34). In
this case the opening must be reinforced by an appropriate frame.
Using the existing roof hatch openings (ventilation hatch) in the vehicle
(chapter “Installing in a roof hatch opening already provided” on page 35).
8.2
Making a new opening
See fig.
3
➤
Select an area at the centre on the roof between two longitudinal sup-
ports.
➤
Mark the position and size of the opening using the template included in
the packaging (
A
and
B
).
See fig.
4
➤
Drill out the corners (
A
).
➤
Carefully cut out the opening on the roof using a keyhole saw or a similar
tool (
B
).
Make sure no electrical power cables are damaged.
See fig.
5
➤
Before installation, check whether the roof hole needs reinforcing.
➤
Remove the foam according to the width of your reinforcing rails (not in
scope of delivery) (
A
).
➤
Fit the reinforcing rails (
B
).