EN
FreshJet
Installation
11
See fig.
8
A
➤
Seal the screw holes and recesses with a flexible non-hardening butyl sealing
compound (e.g. SikaLastomer-710).
8.4
Laying the connecting cables
!
The roof air conditioner must be connected to an electric circuit which is able to
supply the required current (see Technical data in Operating Manual).
➤
Select the cross-section of the cable corresponding to the length:
–
Length < 7.5 m: 1.5 mm²
–
Length > 7.5 m: 2.5 mm²
See fig.
9
➤
Make an opening on one side in order to feed through the electrical power
supply cable.
➤
Feed the 230 V
w
cable through the opening into the vehicle interior.
If the lighting should be switched on without the use of a 230 V
w
voltage supply:
➤
Connect the cable with the positive terminal and the negative terminal of the
vehicle battery.
➤
Feed the 12 V
g
cable through the opening into the vehicle interior.
NOTICE! Damage hazard
Observe the sealant manufacturer’s instructions.
WARNING! Electrocution hazard
Make sure there is no voltage at electrically operated components
before carrying out work on them!
FreshJet-ADB2015_INM_EMEA16.book Seite 11 Dienstag, 3. September 2019 4:33 16