Installing The Mounting Brackets
EnviroComfort Installation Manual
8
L-2657 ENGLISH
Figure 2: Spacing Allowances & Unit Dimensions for Mounting
For specific measurements, see Table 2: Unit Dimensions, below .
I
NSTALLING
T
HE
M
OUNTING
B
RACKETS
The air conditioning unit is supplied with a base pan that also serves as a condensate pan. Use the mounting-clip brackets and
screws (4) to secure the base pan onto a flat, horizontal surface. See Figure 3: Mounting Bracket, below.
Figure 3: Mounting Bracket
I
NSTALLING
T
HE
C
ONDENSATE
D
RAINS
The condensate drain pan is 2.0” (51mm) high with two drain locations. During conditions of high humidity, condensate may be
produced at a rate of approximately one-half gallon (1.9 liter) per hour. With this in mind, it is important to route condensate
drains downward to a sump pump. It is not recommended to route condensate drains to the bilge.
After the condensate drain installation is complete, test the installation by pouring one quart (liter) of water into the pan and
checking for good flow.
To install the condensate drain:
1.
Remove the aft-facing watertight plug from the base pan of the air conditioning unit.
2.
Slip the solid washer and the liquid-seal washer onto the PVC fitting in that order. (See Figure 4: Condensate Drain Kit,
page 9.)
3.
Connect the fitting through the exposed hole in the base pan with the locking nut.
4.
Securely tighten using two (2) wrenches to provide a proper seal.
3” (7.62 cm) Space allowance for
return-air intake if adjacent to
bulkhead
Refrigerant connection
(allow space for access)
EVAPORATOR
&
CONDENSER
COIL
DUCT
RING
ELEC
BOX
ROTARY
COMP
TOP VIEW
SIDE VIEW
BACK VIEW
6” (15.2 m) Space
allowance for
seawater piping
3” (7.62 cm) Space
allowance for electric
blower-motor ventilation
A) Duct
size
1” (2.54cm)
2” (5.08 cm)
Total
min
clearance
Standard
blower position
as shipped
Possible
drain line
location
Remove 7 screws to
rotate blower
BLOWER
D) Width
E) Height
B) Base depth
C) Overall depth
NOTE:
Blower shown in
vertical position
EnviroComfort Unit
Base pan
Mounting bracket