L-2086 Installation
Manifolds
If a pump is serving multiple units, then a seawater manifold
will be needed to supply water to all units. This can be as
simple as a TEE for 2 units, or a custom made manifold for up
to 7 or 8 units.
It is very important to consider manifold orientation so that all
air conditioning units get the proper flow of water. See Figure
10 for manifold information.
A manifold can also be used on the outlets of the air condition-
ing units when using a single overboard discharge.
Overboard Discharge
The overboard fitting should be located between 1 to 2 inches
(25 - 50 mm) above the water line. This is to facilitate visual
confirmation of water flow, but also close enough to the water
to minimize splashing noise.
If the overboard fitting must be installed below the heeled water
line, then a valve must be installed per ABYC standards.
Seawater Piping
•
Only use reinforced marine grade hose or other suitable
piping (PVC, CPVC, Cupronickle, or Stainless steel).
•
Double clamp all hose connections.
•
Use only plastic, bronze, or stainless steel fittings (do not
use brass).
•
Avoid loops or dips in the hose runs.
•
Make sure enough hose is used to allow future removal of
components.
•
Use the correct size hose, fittings, and components. See
the table below for proper seawater sizing. Note that the
pump inlet piping (including through-hull and strainer) may
need to be larger than the outlet pipe size. Do not use
pump connections to determine hose size.
•
The “Pump Inlet” recommended pipe size includes all
fittings and hose (through-hull, seacock, strainer, etc.) up to
the pump inlet connection. The “Pump Discharge” includes
all piping/hose and fittings from the pump to the air condi-
tioning unit or manifold, and to the overboard discharge.
•
Use larger hose when the run is longer than 16 feet (5m).
Bonding
Bond all metallic parts (through-hull fittings, valves, strainer,
manifolds, etc.) that are in contact with seawater to the vessel’s
bonding system in accordance with ABYC standards E-8 and
E-9. Items should only be bonded or grounded once. If an item
is in contact with an electrically grounded part (pump head or
seawater condenser) then it should not be bonded again.
Installing The Air Distribution
System
The following instructions apply to both self-contained units
and remote condensing systems, except as noted. Refer to
Figure 11 for proper grill and duct sizes.
Return Air Grill (RA Grills)
The return air grill should be located so there is unobstructed
airflow to the unit’s evaporator coils. Installing ducting between
the return air grill and the air conditioning unit is not normally
necessary and should be avoided. The grill may be located on
a side opposite the evaporator coil so long as airflow to the coil
is unobstructed.
An air filter must be used to prevent the evaporator coil from
collecting dirt and lint. The filter can be located at the evap-
orator coil or at the grill. Only one filter should be used. Most
self-contained units and cooling units are supplied with an air
filter, but if the filter is not easily accessible, use a filter on the
return air grill.
Ducts
Insulated flexible ducting or built-in ducting may be used to
route air from the blower to the discharge grill. Note that blow
through cooling units are installed directly behind the discharge
grill, and ducts are unnecessary. Likewise, with some overhead
cooling/heating units, air is discharged directly into the com-
partment without ducts.
Ducting Guidelines
Secure duct to blower or transition box (plenum) with screws
and duct tape. When using insulated flexible ducting, make
sure inner duct is secured and sealed to adapter before pulling
insulation over connection.
Содержание DX Remote & Self-Contained A/C
Страница 2: ......
Страница 23: ...23 L 2086 Fig 12 Plenum Configurations Fig 11 Duct and Grill Sizes Tables ...
Страница 24: ...24 L 2086 Fig 13a Switch Dimensions and Templates ...
Страница 25: ...25 L 2086 Fig 13b Switch Dimensions and Templates ...
Страница 26: ...26 L 2086 Fig 14 SHR5 16 StowAway Wiring 082611 Fig 15 SH24C StowAway Wiring 080264 ...
Страница 29: ...29 L 2086 Fig 20 WFAH6 16 Condensing Unit Wiring 082201 Fig 21 R F20 60C 1 Ph Cond Unit Wiring 082534 ...
Страница 30: ...30 L 2086 Fig 22 R F24 72 3 Ph Cond Unit Wiring 082556 Fig 23 SA3 Z Switch Wiring ...
Страница 31: ...31 L 2086 Fig 25 PR3X Pump Relay Wiring Fig 24 SA5 Z Switch Wiring ...
Страница 32: ...32 L 2086 Fig 26 PR8X Pump Relay Wiring Fig 27 WFAH System Wiring 115V ...
Страница 33: ...33 L 2086 Fig 28 WFAH System Wiring 230V Fig 29 WFAH System Wiring 230V w Aux Heat ...
Страница 34: ...34 L 2086 Fig 30 R F Type System Wiring SA3 Z Switch 1Ph Fig 31 R F Type System Wiring SA3 B Switch 1Ph ...
Страница 35: ...35 L 2086 Fig 32 R F Type System Wiring SA3 Z Switch 3Ph ...
Страница 36: ...36 L 2086 Fig 33 Refrigerant Charging Curves R22 ...
Страница 38: ...NOTES ...
Страница 39: ...NOTES ...