![Dometic DSP-EM Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/dometic/dsp-em/dsp-em_service-manual_2518805007.webp)
7
EN
DSP-EM
Service codes
I
NOTE
The service codes from S-15 up to and including S-21 must only be used if you
are not using a battery sensor.
Service code
Description
Range
Stand
ard
value
Device
S-15
End-of-charge voltage
Sets the end-of-charge voltage.
Note:
Observe the information from the
battery manufacturer
13.5 V to 15 V
in 0.1 V intervals
14.4 V
DSP-C
S-16
Float charge voltage
Sets the float charge voltage.
Note:
Observe the information from the
battery manufacturer
12.8 V to 14.3 V
in 0.1 V intervals
13.6 V
DSP-C
S-17
Bulk timer
Duration of the I phase
Sets the maximum time during which the
battery is charged with maximum
current.
0.5 h to 20 h
in 0.5 h intervals
8 h
DSP-C
S-18
Absorption timer
Duration of the
U0 phase
Sets the maximum time during which the
battery is charged with the
end-of-charge voltage.
0.5 h to 10 h
in 0.5 h intervals
6 h
DSP-C
S-19
Battery cable length
Sets the length of the cable between the
battery and the DSP-C inverter in order
to compensate for the voltage drop.
Note:
Incorrect values can damage the battery
0.1 m to 5 m
in 0.1 m intervals
0.1 m
DSP-C
S-20
Cable cross section
Sets the cable cross section in order to
compensate for the voltage drop.
Note:
Incorrect values can damage the battery
16 mm
2
, 25 mm
2
,
35 mm
2
, 50 mm
2
,
70 mm
2
, 95 mm
2
95 m
2
DSP-C
S-21
Emergency vehicle
charging mode
Switches the emergency vehicle
charging mode ON/OFF.
ON, OFF
OFF
DSP-C
DSP-EM-Service-16s.book Seite 7 Dienstag, 29. Januar 2019 3:08 15