5
FIG. 3
Mounting Rail
3″ Screw
FIG. 4
Base Cover
3″ Screw
INSTALL REFRIGERATOR
CONNECT UTILITIES
1.
Connect water (if applicable) and electric ser-
vices to refrigerator.
See Installation Instructions (included with
refrigerator) for complete instructions.
2.
ALWAYS
use a backup wrench
when loosening or tightening LP gas connec-
tions.
Connect LP gas service.
See Installation Instructions (included with
refrigerator) for complete instructions.
a. If RV LP gas line is long enough to reach
LP gas valve on refrigerator, skip to section
"Finish Installation" on page (6).
Gas line extension is
NOT
needed if
existing RV LP gas line is long enough.
b. If RV LP gas line does not reach LP gas
valve on refrigerator, proceed to step (c).
c.
Connect gas line extension to RV LP gas
line. See (FIG. 5) & (FIG. 6).
● Place and tighten 3/8″ flare nipple (pro
-
vided with gas line extension) into flare
nut of RV LP gas line.
FIG. 5
Gas Line
Extension
LP Gas Line
(From RV)
3/8″ Flare
Nipple
FIG. 6
3/8″ Flare
Nipple
Backup
Wrench
Gas Line
Extension
Line
Wrench
d.
Connect gas line extension to LP gas valve
on refrigerator. See (FIG. 7).
It may be necessary to loop gas line
extension.
● Place and tighten flare nut of gas line ex
-
tension (provided) onto 3/8″ male flare
end of refrigerator LP gas valve.
FIG. 7
Gas Line Extension
(Shown Looped)
Line
Wrench
Backup
Wrench
LP gas valve