EN
CFF35, CFF45
Operation
15
A
For safety reasons the cooler is equipped with an electronic system to prevent
polarity reversal. This protects the cooler against short-circuiting when connecting to
a battery.
Using the fused DC plug
A
➤
Plug the DC connection cable (fig.
1
2, page 7) into the DC voltage socket of
the cooler (fig.
4
3, page 11).
➤
Connect the connection cable to a DC power outlet.
Connecting to an AC power supply (e.g. in the home or office)
D
The coolers have an integrated multi-voltage power supply with priority circuit for
connecting to an AC voltage source. The priority circuit automatically switches the
cooler to AC operation if the device is connected to an AC power supply, even if the
DC connection cable is still attached.
NOTICE!
DAMAGE HAZARD!
Failure to obey this instruction may result in damage to the device.
Disconnect the cooler and other consumer units from the battery before
you connect the battery to a quick charging device.
Overvoltage can damage the electronics of the device.
NOTICE!
DAMAGE HAZARD!
Failure to obey this instruction may result in damage to the device.
For protection of the device the DC cable supplied includes a fuse inside
the plug. Do
not
remove the fused DC plug.
Only use the DC cable supplied.
DANGER!
ELECTROCUTION HAZARD!
Failure to obey these warnings will result in death or serious injury.
•
Never handle plugs and switches with wet hands or if you are
standing on a wet surface.
•
If you are operating your cooler on board a boat from a AC power
supply, you must install a residual current circuit breaker between the
AC power supply and the cooler.
Seek advice from a trained technician.
DometicCFF35-45_O_4445102755_AMER4_.book Seite 15 Freitag, 10. Januar 2020 12:50 12