EN
Operation
ACX35, ACX40, ACX40G
20
➤
Push the sleeve of the hose line (
3
) into the safety coupling (
5
) until you hear it
latch.
➤
Open the valve (
6
) on the safety coupling (
5
).
➤
Open the valve of the gas cylinder or container.
!
➤
Check all connections with leak spray.
There are no leaks at the connections if
no
bubbles form.
Disconnecting the cooler from the external gas supply
➤
Close the valve (
6
) of the safety coupling (
5
) of the gas port.
➤
Disconnect the hose line (
2
) by pushing the sleeve towards the valve handle.
➤
Put the cap (
4
) onto the safety coupling (
5
).
➤
Turn the temperature controller (fig.
3
2, page 5) to “
”.
6.6
Connecting the ACX35 or ACX40 cooler to a gas
cylinder
Note the following country-specific gas type and gas pressure categories:
➤
Connect the ACX35 or ACX40 cooler to the gas hose (fig.
6
, page 7) and the
gas cylinder (fig.
7
, page 8).
WARNING!
Never check for leaks with an open flame or near sources of ignition.
Country
Device categories
Denmark, Finland, Hungary, Norway, Poland, Sweden I
3
B/P – 30 mbar
Belgium, Czech Republic, France, Italy, The Nether-
lands, Portugal, Slovakia, Spain, United Kingdom
I
3
+ – 28 – 30 / 37 mbar
Austria, Germany, Luxembourg, Switzerland
I
3
B/P – 50 mbar