The display shows the charging status.
➤
If charging the battery pack with a solar panel, observe the following require-
ments:
–
Use without a solar controller:
Ensure that the solar panel outputs between 8 – 25 V DC and a maximum
charging current of 10 A.
–
Use with a solar controller:
Ensure the solar charger does not need a counter voltage from the battery
side to start charging. Ensure that the maximum charging current is 10 A
(check with the solar panel manufacturer).
6.4
Checking the charge level
➤
Press the power button (fig.
✔
The display shows the battery state of charge as a percentage.
✔
The
symbol flashes when the battery capacity is below 20 %.
6.5
Connecting consumer devices
➤
Open the cap for the desired device:
–
USB devices (
3
)
–
2-pin 12 V DC socket outlet (
4
)
–
12 V DC socket (
5
)
➤
Insert your device’s plug into the corresponding socket.
✔
The
symbol and the related output symbol light up.
6.6
Replacing fuses
➤
Ensure that the battery pack is not connected to AC/DC or DC/DC charger.
➤
Disconnect all loads.
➤
Press the power button for at least 3 s to switch the battery pack off.
➤
Undo the fuse holder.
➤
Replace the fuse with a 20 A 3 AG glass-slow acting fuse.
DometicPLB40_OPM_4445102672_EMEA16_20xx-xx-xx.book Seite 13 Dienstag, 26. Januar 2021 4:43 16
Содержание 9600014024
Страница 162: ...RU PLB40 162 A 2 2 1 DometicPLB40_OPM_4445102672_EMEA16_20xx xx xx book Seite 162 Dienstag 26 Januar 2021 4 43 16...
Страница 164: ...RU PLB40 164 2 2 A DometicPLB40_OPM_4445102672_EMEA16_20xx xx xx book Seite 164 Dienstag 26 Januar 2021 4 43 16...
Страница 233: ...DometicPLB40_OPM_4445102672_EMEA16_20xx xx xx book Seite 233 Dienstag 26 Januar 2021 4 43 16...
Страница 234: ...DometicPLB40_OPM_4445102672_EMEA16_20xx xx xx book Seite 234 Dienstag 26 Januar 2021 4 43 16...
Страница 235: ...DometicPLB40_OPM_4445102672_EMEA16_20xx xx xx book Seite 235 Dienstag 26 Januar 2021 4 43 16...