EN
FreshJet
Installation
11
Note on electrical system
•
Only a qualified electrician should connect the roof air conditioner to the
electrical power.
•
Check that the voltage specification on the type plate is the same as that of the
power supply.
•
If the lighting should also be switched on without a 230 V voltage supply, make
sure that there is a 12 V
g
power supply line from the battery to the roof air
conditioner.
•
Do not lay the 230 V mains cable and the 12/24 V
g
cable together in the same
cable duct.
•
Do not lay cables which are loose or bent next to electrically conductive material
(metal).
•
Install an all-pole switch with a contact opening width of at least 3 mm on the
installation side.
There are two ways of installing the roof air conditioner:
•
Making a new opening (chapter “Making a new opening” on page 11). In this
case the opening must be reinforced by an appropriate frame.
•
Using the existing roof hatch openings (ventilation hatch) in the vehicle (chapter
“Installing in a roof hatch opening already provided” on page 12).
8.2
Making a new opening
See fig.
3
➤
Select an area at the centre on the roof between two longitudinal supports.
➤
Mark the position and size of the opening using the template included in the
packaging (
A
and
B
).
See fig.
4
➤
Drill out the corners (
A
).
➤
Carefully cut out the opening on the roof using a keyhole saw or a similar tool (
B
).
Make sure no electrical power cables are damaged.
FreshJet-ADB2015-I-16s.book Seite 11 Mittwoch, 8. März 2017 9:13 21
Содержание 9105306511
Страница 6: ......
Страница 203: ...DA FreshJet Tekniske data 199 Vægt ca 36 kg Godkendelse certifikat FreshJet 3200 ...
Страница 321: ...PL FreshJet Dane techniczne 317 ...
Страница 341: ...SK FreshJet Technické údaje 337 11 Technické údaje Obsahuje fluórované skleníkové plyny Hermeticky uzavreté zariadenie ...
Страница 391: ......