Dometic 620515.321 Скачать руководство пользователя страница 3

3

Model

Nominal

Electrical

Compressor

Compressor

Fan Motor

Fan Motor

S

C

F

M-High

Total

Refrigerant

Minimum

A

C

 Circuit

Installed

Minimum

N

o

.

Capacity

Rating

Rated Load

Locked

Rated Load

Locked

S

p

e

e

d

Static

R-22 (Oz.)

Wire 

Size*

P

rotection

Weight

Generator

(BTU/HR)

Amps

R

o

to

r

Amps

Rotor

Max/Min

Max/Min

***User

(Pounds)

Size**

Cooling

Amps

Amps

W.C.

Supplied

1Unit/2Units

620515.321

13,500

115 VAC,

12.4

60.0

3

.1

8

.8

335 /250

0

.1

2

/0

.6

5

15.5

12AWG

2

0

 A

m

p

1

0

2

3.5 KW/5.0 KW

620515.326

13,500

6

0

 Hz., 1 PH

12.4

60.0

3

.1

8

.8

335/250

0.12/0.65

15.5

Copper

20 

Amp

1

0

2

3.5 KW/5.0 KW

620515.421

13,500

11.5

50.0

3

.1

8

.8

335/250

0.12  /  0.65

17.0

U

p

 T

o

 2

4

'

2

0

 A

m

p

1

0

2

3.5 KW/5.0 KW

620525.321

13,500

12.4

60.0

3

.1

8

.8

335  / 250

0

.1

2

/0

.6

5

15.5

2

0

 A

m

p

1

0

2

3.5 KW/5.0 KW

620525.326

13,500

12.4

60.0

3

.1

8

.8

335/250

0.12/0.65

15.5

2

0

 A

m

p

1

0

2

3.5 KW/5.0 KW

620525.421

13,500

11.5

50.0

3

.1

8

.8

335/250

0.12/0.65

17.0

2

0

 A

m

p

1

0

2

3.5 KW/5.0 KW

620526.321

15,000

12.0

64.0

3

.3

8

.5

380/250

0.12/0.65

21.5

2

0

 A

m

p

1

0

4

3.5 KW/5.0 KW

620526.326

15,000

12.0

64.0

3

.3

8

.5

380/250

0.12/0.65

21.5

2

0

 A

m

p

1

0

4

3.5 KW/5.0 KW

630515.321

13,500

12.4

60.0

3

.1

8

.8

335/250

0.12/0.65

24.5

2

0

 A

m

p

1

0

2

3.5 KW/5.0 KW

630515.326

13,500

12.4

60.0

3

.1

8

.8

335/250

0.12/0.65

24.5

2

0

 A

m

p

1

0

2

3.5 KW/5.0 KW

630515.421

13,500

12.0

50.0

3

.1

8

.8

335/250

0.12/0.65

19.5

2

0

 A

m

p

1

0

2

3.5 KW/5.0 KW

630516.321

15,000

12.0

64.0

3

.3

8

.5

380/250

0.12/0.65

21.5

2

0

 A

m

p

1

0

4

3.5 KW/ 5.0 KW

630516.326

15,000

12.0

64.0

3

.3

8

.5

380/250

0.12/0.65

21.5

2

0

 A

m

p

1

0

4

3.5 KW/5.0 KW

SPECIFICA

TIONS

*

For wire length over 24 ft., consult the National Electric Code for proper sizing.

**

Dometic Corporation gives 

GENERAL

 guidelines for generator  requirements. These guidelines come from experiences people have had in actual applications.

When sizing the generator, the total power usage of your recreational vehicle must be considered. Keep in mind generators lose 

power at high altitudes

a

n

d

from lack of maintenance.

**

*

CIRCUIT PROTECTION: Time Delay Fuse or HACR Circuit Breakers Required.

620515, 620525, 620526, 630515 & 630516 Installation Instructions

Содержание 620515.321

Страница 1: ...UNITINFORMATIONFOR FUTUREREFERENCE Model Number Serial Number Date Purchased This manual must be read and un derstood before installation ad justment service or maintenance is performed This unit must...

Страница 2: ...gain accesso ries like A E outdoor patio and window awnings will reduce heat gain by removing the direct sun They also add a nice area to enjoy company during the cool of the evening D Condensation N...

Страница 3: ...0 64 0 3 3 8 5 380 250 0 12 0 65 21 5 20 Amp 104 3 5 KW 5 0 KW 620526 326 15 000 12 0 64 0 3 3 8 5 380 250 0 12 0 65 21 5 20 Amp 104 3 5 KW 5 0 KW 630515 321 13 500 12 4 60 0 3 1 8 8 335 250 0 12 0 65...

Страница 4: ...ed slightly forward of center front to back and centered from side to side b For two unit installations Install one Air Condi tioner 1 3 and one Air Conditioner 2 3 s from front of RV and centered fro...

Страница 5: ...ished in accordance with NFPA Standard 501C Section 2 7 2 Do Not Cut RoofStrucure OrRafters Good Rafters Supported By CrossBeams Good Location Between Roof Rafters 2 RoofVentRemoval a Unscrewandremove...

Страница 6: ...7180 006 Bolt Cover Kit has the mounting bolts and cover for the AC junction box for use with these kits D Wiring Requirments 1 Route a copper 12 AWG with ground 115 VAC supplylinefromthefuseorcircuit...

Страница 7: ...0 Sq In Min Duct Size Depth 1 1 2 In Min 2 1 2 In Max 2 0 In Min 2 1 2 In Max Width 7 0 In Min 10 0 In Max 8 0 In Min 10 0 In Max Total Duct Length 15 0 Ft Min 40 0 Ft Max 15 0 Ft Min 40 0 Ft Max Duc...

Страница 8: ...4 conductortelephonecable c The control cable must be terminated with two 2 RJ 11 telephone connectors Refer to the crimp tool manufacture for crimping instruc tions Important RJ 11 connectors must be...

Страница 9: ...from the carton and discard carton 2 Place the air conditioner on the roof FIG 11 CAUTION FIG 12 FRONT G Installing Air Conditioner Installing unit with 3105007 XXX or 3105935 XXX Return Air Cover For...

Страница 10: ...g See FIG 16 EVENLY tighten the bolts to a torque of 40 to 50 inch pounds This will compress the roof gasket to approximately 1 2 The bolts are self locking so over tight ening is not necessary See FI...

Страница 11: ...th the center discharge duct go to page 12 Section 2 Center Duct In stallation a Check gasket alignment of the air conditioner over the roof opening and adjust if necessary Unit may be moved from belo...

Страница 12: ...t s electrical cord and fas ten the junction box with screws to the framing in the front of the 14 1 4 x 14 1 4 1 8 opening See FIG 19 Install the Romex connector in the junc tion box b Installing Foa...

Страница 13: ...ate off d Push the wires into the box e Install the cover onto the junction box Improper installation and sealing of foam di viderwillcausethecompressortoquickcycle on the cold control This may result...

Страница 14: ...AGE GEN START 3 Install cover to template with 8 x 3 8 blunt point Phillips head screws provided 6 required 4 Reinstall filter return air grill into return air cover Align tabs with mating notches and...

Страница 15: ...reate a condition where the normal Differential will not maintain your comfortzone Ifthisoccurs theDifferentialcan be shortened by placing the Differential dip switch in the ON position Note Setting t...

Страница 16: ...NACE 2 WIRES OPTIONAL FRONT REMOTE SENSOR OPTIONAL FRONT REMOTE SENSOR 12V DC INPUT 2 WIRES 12V DC INPUT 2 WIRES FURNACE 4 CONDUCTOR CONTROL CABLE 4 CONDUCTOR CONTROL CABLE BREAKER BOX BREAKER BOX 115...

Страница 17: ...EL BLU YEL P6 COM K1 NO WHITE F1 P4 P3 P5 AMBIENT AMBIENT SENSOR SENSOR P2 DIELECTRIC PASSED SENSOR CABLE CABLE REMOTE FREEZE CONTROL BLK RED BRN FAN RUN CAP RUN CAP HERM C REVERSING VALVE REVERSING V...

Отзывы: