11

Note: The adhesive on the insulation is extremely sticky.
Be sure the part is located where desired before pressing
into place.

d. With slight pressure then push the divider plate

against the double sided tape on the ceiling
template.

e. Locate the 1/8" x 7" x 18" self -adhesive insula-

tion supplied with the return air kit. Remove the
backing paper from the insulation and carefully
stick onto the ceiling template divider panel.
See FIG. 19.

Excess width is intended to seal the di-
vider plate to the sides of the 14-1/4" x 14-
1/4" (±1/8") opening. This is to help pre-
vent cold air discharge from circulating into
the air conditioner return air opening.

If the insulation is too high, stick excess
height of insulation to the air conditioner
base pan. Do not cover up unit rating plate.

FIG. 19

Installing unit with 3308120.XXX Genesis Air Fil-

tration System Return Air Kit. For unit with
3105007.XXX or 3105935.XXX Return Air Kit, see
page 9.

Micro-Therm Filter System

Micro-Therm Filter System

FILTER
RESET

FILTER
RESET

CLEA

N

FILTE

R

CLEAN
FILTER

Return Air
Cover

FIG. 20

Grill

Foam
Divider

Ceiling
Template

Slider

Filter

Handle

1.

All Non-Center Duct Installations

Note: The Genesis Air Filtration System can be installed on
the units that use a center discharge duct through the 14-1/
4" x 14-1/4" (±1/8") opening. Installing units with the center
discharge duct go to page 12 "Section 2" Center Duct In-
stallation.

a.

Check gasket alignment of the air conditioner
over the roof opening and adjust if necessary.
Unit may be moved from below by slightly lift-
ing. See FIG. 14.

Remove return air cover, ceiling template,

foam divider and air filter from the 3308120
carton.

Locate the four 8" x 1/4" x 20 unit mount-

ing bolts, junction box cover and Romex
connector in the 3107180.006 bolt kit.

Install the Romex connector in the junc-

tion box.

Pull down the unit's electrical cord and fas-

ten the junction box with screws to the fram-
ing in the front of the 14-1/4" x 14-1/4" (±1/

8") opening. See FIG. 15.

b.

Installing Foam Divider

Locate the foam divider and insert it corner
to corner in the  14-1/4" x 14-1/4" (±1/8")
opening with the adhesive tape up. (Do not
remove paper to expose adhesive). The
foam divider should be level with the ceiling
(±1/4"). Tear off the excess at the pre-cut
perforations in divider. See FIG. 21.

FIG. 21

Upside
Down
Foam
Divider

Base Pan

Ceiling

Place Foam Divider In
(14-1/4" x 14-1/4" (±1/8")
Ceiling Opening Against Base
Pan Bottom

Do Not Peel Tape Off
Adhesive

Foam Divider Ceiling
Level 

(±1/4")

 Tear Off

Excess

FIG. 22

Foam Divider

Adhesive

Peel Off Paper - Center Divider - Stick To
Rear Flange On Ceiling Template

c.

Install Ceiling Template

Peel the paper off of the foam divider and
stick it in place on the center of the rear
flange of the return air opening on the ceil-
ing template. See FIG. 22.

620515, 620525, 620526, 630515 & 630516 Installation Instructions

Содержание 620515.321

Страница 1: ...UNITINFORMATIONFOR FUTUREREFERENCE Model Number Serial Number Date Purchased This manual must be read and un derstood before installation ad justment service or maintenance is performed This unit must...

Страница 2: ...gain accesso ries like A E outdoor patio and window awnings will reduce heat gain by removing the direct sun They also add a nice area to enjoy company during the cool of the evening D Condensation N...

Страница 3: ...0 64 0 3 3 8 5 380 250 0 12 0 65 21 5 20 Amp 104 3 5 KW 5 0 KW 620526 326 15 000 12 0 64 0 3 3 8 5 380 250 0 12 0 65 21 5 20 Amp 104 3 5 KW 5 0 KW 630515 321 13 500 12 4 60 0 3 1 8 8 335 250 0 12 0 65...

Страница 4: ...ed slightly forward of center front to back and centered from side to side b For two unit installations Install one Air Condi tioner 1 3 and one Air Conditioner 2 3 s from front of RV and centered fro...

Страница 5: ...ished in accordance with NFPA Standard 501C Section 2 7 2 Do Not Cut RoofStrucure OrRafters Good Rafters Supported By CrossBeams Good Location Between Roof Rafters 2 RoofVentRemoval a Unscrewandremove...

Страница 6: ...7180 006 Bolt Cover Kit has the mounting bolts and cover for the AC junction box for use with these kits D Wiring Requirments 1 Route a copper 12 AWG with ground 115 VAC supplylinefromthefuseorcircuit...

Страница 7: ...0 Sq In Min Duct Size Depth 1 1 2 In Min 2 1 2 In Max 2 0 In Min 2 1 2 In Max Width 7 0 In Min 10 0 In Max 8 0 In Min 10 0 In Max Total Duct Length 15 0 Ft Min 40 0 Ft Max 15 0 Ft Min 40 0 Ft Max Duc...

Страница 8: ...4 conductortelephonecable c The control cable must be terminated with two 2 RJ 11 telephone connectors Refer to the crimp tool manufacture for crimping instruc tions Important RJ 11 connectors must be...

Страница 9: ...from the carton and discard carton 2 Place the air conditioner on the roof FIG 11 CAUTION FIG 12 FRONT G Installing Air Conditioner Installing unit with 3105007 XXX or 3105935 XXX Return Air Cover For...

Страница 10: ...g See FIG 16 EVENLY tighten the bolts to a torque of 40 to 50 inch pounds This will compress the roof gasket to approximately 1 2 The bolts are self locking so over tight ening is not necessary See FI...

Страница 11: ...th the center discharge duct go to page 12 Section 2 Center Duct In stallation a Check gasket alignment of the air conditioner over the roof opening and adjust if necessary Unit may be moved from belo...

Страница 12: ...t s electrical cord and fas ten the junction box with screws to the framing in the front of the 14 1 4 x 14 1 4 1 8 opening See FIG 19 Install the Romex connector in the junc tion box b Installing Foa...

Страница 13: ...ate off d Push the wires into the box e Install the cover onto the junction box Improper installation and sealing of foam di viderwillcausethecompressortoquickcycle on the cold control This may result...

Страница 14: ...AGE GEN START 3 Install cover to template with 8 x 3 8 blunt point Phillips head screws provided 6 required 4 Reinstall filter return air grill into return air cover Align tabs with mating notches and...

Страница 15: ...reate a condition where the normal Differential will not maintain your comfortzone Ifthisoccurs theDifferentialcan be shortened by placing the Differential dip switch in the ON position Note Setting t...

Страница 16: ...NACE 2 WIRES OPTIONAL FRONT REMOTE SENSOR OPTIONAL FRONT REMOTE SENSOR 12V DC INPUT 2 WIRES 12V DC INPUT 2 WIRES FURNACE 4 CONDUCTOR CONTROL CABLE 4 CONDUCTOR CONTROL CABLE BREAKER BOX BREAKER BOX 115...

Страница 17: ...EL BLU YEL P6 COM K1 NO WHITE F1 P4 P3 P5 AMBIENT AMBIENT SENSOR SENSOR P2 DIELECTRIC PASSED SENSOR CABLE CABLE REMOTE FREEZE CONTROL BLK RED BRN FAN RUN CAP RUN CAP HERM C REVERSING VALVE REVERSING V...

Отзывы: