Troubleshooting
17
12
Troubleshooting
Compressor does not run
Fault
Possible cause
Remedy
U
T
= 0 V
The connection between the battery
and the electronics is interrupted
Establish a connection
Main switch defective (if installed)
Replace the main switch
Additional supply line fuse has blown
(if installed)
Replacing the fuse
U
T
U
ON
Battery voltage is too low
Charge the battery
Start attempt with
U
T
U
OFF
Loose cables
Poor contact (corrosion)
Establish a connection
Battery capacity too low
Replace the battery
Cable cross section too low
Replace the cable
(fig.
4
, page 4)
Start attempt with
U
T
U
ON
Ambient temperature too high
–
Insufficient ventilation
Move the cooling device
Condenser is dirty
Clean the condenser
Fan defective (if installed)
Replace the fan
U
T
Voltage between the positive and negative electronic terminals
U
ON
Switch-on voltage of the electronics
U
OFF
Switch-off voltage of the electronics