MAINTENANCE
A. Air Filter
1. Periodically (a minimum of every 2 weeks of opera-
tion) slide out the return air filters located on the
end of the air distribution box. Wash the filters with
soap and warm water, let dry and then reinstall.
Note:
To insure easy future removal the filters need to be
replaced with the domed side of their handle positioned
towards the ceiling.
Note:
Never run the unit without both return air filters in
place. This will plug the unit evaporator coil with dirt and may
substantially degrade the performance of the unit over time.
B. Air Distribution Box Housing
1. Clean air distribution box housing and control panel
with a soft cloth dampened with a mild detergent.
Never use furniture polish or scouring powders.
C. Fan Motor
1. The blower motor is factory lubricated and requires
no service.
SERVICE-UNIT DOES NOT OPERATE
If your unit fails to operate or operates improperly, check
the following before calling your service center.
A.
If Caravan connected to motor generator, check to
be sure motor generator is running and producing
power.
B.
If Caravan connected to power supply by a land line,
check to be sure line is sized properly to run unit load
and it is plugged into power supply.
C.
Check your fuse or circuit breaker to see if it is open.
Insure fuse is not burnt, or circuit breaker is "ON" and
not activated.
D.
After the above checks, call your local service center
for further help. This unit must be serviced by qualified
service personnel only.
E.
If any wiring or supply cord is damaged and
needs to be replaced, it must be replaced by the
manufacturer or its service agent or a similarly quali-
fied person.
F.
When calling for service, always give the following:
1. Unit type and serial number found on identification
label located on base pan of unit bottom. (Remove
filter and view through network of holes)
2. Air distribution box model and serial number found
on rating plate located on ceiling template. Observe
this rating plate through the air distribution box right
side vent opening.
Dometic Australia Pty Ltd
ABN 620 086 366 305
PO Box 1140
Clayton South
Vic 3169
Tel: 03 9239 1000
Fax: 03 9239 1099
Содержание 3241CX51R