![background image](http://html.mh-extra.com/html/dometic-group/waeco-coolpower-mps35/waeco-coolpower-mps35_installation-and-operating-manual_2519724017.webp)
EN
CoolPower MPS35
Technical description
17
5
Technical description
The mains rectifier can operate all coolers and refrigerators with BD35F com-
pressors at 110 – 240 V~.
With a 110 – 240 V~ mains connection, the rectifier automatically switches
from battery to mains operation.
When disconnected from the 110 – 240 V~ mains supply, the rectifier auto-
matically switches back to battery operation. Mains operation via the rectifier
always takes priority over battery operation.
5.1
Control elements
6
Mounting the mains rectifier
If you wish to mount the mains rectifier in a fixed position, please observe the
following
mounting instructions
:
A
NOTICE!
Fix the mains rectifier in upright position only. In case you have to
install the rectifier in a different position put the rectifier in a fire
resistant housing to prevent any fire being roused to other objects
by hot plastic tripping through the air slots.
Do
not
mount the device
– In wet or damp environments
– In the vicinity of combustible materials
– In areas where there is a danger of explosions
Make sure the socket is near the device and is easily accessible.
Item
in fig.
1
, page 3
Explanation
1
Mains cable
2
Battery input terminals
3
Compressor output terminals
4
Fastening holes