DOMEL
EC – Controller Compacto
V2.0, July 2014
Operating and installation Instructions
16
Default Configuration (set by Domel):
MODBUS address:
1
Baud Rate:
19200
START Bit:
1
STOP Bit:
1
Parity:
NONE
Supported MODBUS commands:
0x01: Read Coils
0x02: Read Input
0x03: Read Holding Registers
0x04: Read Input Register
0x05: Write Single Coil
0x06: Write Single Holding Register
To connect PC and DOMEL Compacto Drive over serial line (MODBUS) RS-232/USB to RS-485
Converter is needed. We recommend ADAM-4561 converter. To attach the ADAM-4561 to a PC, you
do not need to power down your PC. The power for the ADAM-4561 converter is derived from the USB
port, so there are no power adapters to deal with.
The ADAM-4561 device driver can be used in combination with Windows 2000/XP/Vista/7 (32 & 64-
bit).