background image

Technical Information  |  11

Cleaning the display

Observe the following guidelines to maintain the display and the LCD screen.

• Use a clean, lint-free, absorbent cotton cloth to clear off any residual glue 

from removal of the protective film or to remove surface dust. Apply light 
pressure to remove the dust.

• Dampen a clean cloth with a small amount of isopropyl alcohol to 

remove glue or dust if the screen is still not clean. Do not saturate the 
cloth; otherwise, alcohol may seep into the display case and collect in the 
enclosure. Use a clean, dry cloth to completely remove the alcohol residue.

• Do not use chemically treated dust cloths, acetone, toluene, or harsh 

solvents on the display case or the screen. They can damage the polarizer 
and the display case.

• Do not expose the display to water or excessive moisture. Do not allow 

water or other stains to stand on the unit. Wipe liquids off immediately to 

prevent damage to the display case and the screen.

Shipping/storing the display

Keep the display in its shipping container until installation. Return the display 
to its original container whenever you need to store the unit, move it to 
another location, or return it for repair. The packaging supplied by the 
manufacturer protects the display while it is in transit. See environment 
specifications for more information.

Before returning the display to the container, do the following:

1 Swivel the display panel to landscape mode.

2 Push the panel down to the lowest position.

3 Use the stand lock to anchor the panel.

Disposal information

Follow your local governing ordinance and recycling policy for 
proper disposal or recycling of display components.

WARNING

DISCONNECT SUPPLY BEFORE SERVICING

AVERTISSEMENT

COUPER L’ALIMENTATION AVANT L’ENTRETIEN ET LE DEPANNAGE

Содержание Sx

Страница 1: ...Dome Sx Display User s Guide ...

Страница 2: ...ucts from other vendors does not imply any recommendation or endorsement This document contains proprietary information protected by copyright No part of this manual may be reproduced by any mechanical electronic or other means in any form without prior written permission of NDSsi NDS Surgical Imaging NDSsi the NDSsi logo Dome the Dome by NDSsi logo Dome S3 Dome S3c Dome S10 Dome CXtra RightLight ...

Страница 3: ...COM Part 14 Standard The all digital design enables the display to produce the sharp crisp images critical to softcopy medical viewing Unwanted analog display image artifacts are eliminated For display classification and use environmental guidelines safety precautions handling cleaning and storage tip and specifications see Technical Information on page 7 System Requirements Windows 7 x86 or x64 o...

Страница 4: ...display packages DVI and mini USB cables ship in the Dome S10 display package The Dome S10 display shown here for illustrative purposes Your display package may contain a Dome S3 Dome S3c or Dome S10 unit DC power adapter Power cord DVI cable DisplayPort cable Mini USB cable Quick reference ...

Страница 5: ...ront of the Dome S3 and Dome S3c displays allows you to run an auto conformance test without using a photometer The MQSA Mammography Quality Standards Act button lower right beneath display ID on the Dome S10 display facilitates any daily weekly or annual tests that you have preset via calibration and monitoring software Front sensor on Dome S3 Dome S3c MQSA button on Dome S10 ...

Страница 6: ...Dome S3c uplink B port Usage to be defined at a future time Dome S10 uplink mini B port Usage assigned for MQSA button functionality Video input Drives the data to the display The Dome S3 Dome S3c display offers two video connector options a standard DVI connector or a DisplayPort connector The Dome S10 display offers two standard DVI connectors Reset button Restores the display configuration to d...

Страница 7: ...e video cable into the video port on the connector plate Secure the connection 2 Plug the power cord into the power input port on the connector plate 3 Plug the other end of the cable into the video port on your computer system Secure the connection 4 Plug the other end of the power cord into the power supply 5 Plug the power supply cord s into a grounded AC outlet 6 Turn on the adapter power befo...

Страница 8: ...Display Note the location of the primary input on the Dome S10 display shown below for proper video cable installation Improper connection may cause VGA boot messages not to appear on the display screen Primary video signal input on the Dome S10 connector plate ...

Страница 9: ...us oxide Mode of Operation Continuous No applied part Important recycle instruction HAZARDOUS SUBSTANCE Lamp s inside this product contain mercury This product may contain other electronic waste that can be hazardous if not disposed of properly Recycle or dispose in accordance with local state or federal laws For more information contact the Telecommunications Industry Association at WWW ECYCLINGC...

Страница 10: ... and analysis by trained medical practitioners IMPORTANT Only the Dome S10 display can be used for review and analysis in mammography Do not use the Dome S3 or Dome S3c display in mammography review and analysis Federal law restricts this device to sale by or on the order of a medical practitioner CAUTION Read the accompanying text carefully for proper operation and maintenance of the display syst...

Страница 11: ...S CONNECTED TO AN EQUIVALENT RECEPTABLE MARKED HOSPITAL ONLY OR HOSPITAL GRADE Safety tips Never open the display case even when the power is off Dangerous voltage inside may cause electric shock or death To avoid damage to the display use the grounded power supply and video cable supplied by NDSsi or use certified replacements Be sure the display is electrically grounded You must connect the thir...

Страница 12: ...nto a standard VESA 100 mm mounting unit if you elect not to use the desk stand Do not set up the display near strong light or heat sources Do not block the vents on the back of the display or install the display in a built in enclosure Blocked vents cause excessive heat to build up inside the display increasing risk of fire When installing components turn off your computer but leave it plugged in...

Страница 13: ...to water or excessive moisture Do not allow water or other stains to stand on the unit Wipe liquids off immediately to prevent damage to the display case and the screen Shipping storing the display Keep the display in its shipping container until installation Return the display to its original container whenever you need to store the unit move it to another location or return it for repair The pac...

Страница 14: ...7 ms typical Viewing angle CR 10 1 170 85 horizontal vertical Interface Digital Video In DVI Rev 1 0 digital dual channel connector DisplayPort Revision 1 1a connector Display control brightness contrast DDC2B Display identification EDID read using DDC2B USB hub on stand N A USB uplink on display Universal Serial Bus Rev 2 0 1 uplink B port Display status Dual stack tricolor LEDs on back of unit I...

Страница 15: ...0 60 Hz Power consumption Wattage 90 W typical Power output requirements Voltage 12 V DC 5 Current 10 8 A 130 W Physical Size 228 6 mm x 76 2 mm x 50 8 mm 9 in x 3 in x 2 in Weight 1 3 kg 2 75 lb Characteristic item Specification Display MTBF 50 000 hours Backlight MTBF 50 000 hours to 50 brightness with backlight on continuously Characteristic item Specification EMI shielding No emission of low l...

Страница 16: ...wing angle CR 10 1 170 85 horizontal vertical Interface Digital Video In DVI Rev 1 0 digital dual channel connector DisplayPort Revision 1 1a connector Display control brightness contrast DDC2B Display identification EDID read using DDC2B USB hub on stand N A USB uplink on display Universal Serial Bus Rev 2 0 1 uplink B port Display status Dual stack tricolor LEDs on back of unit Input formats Lan...

Страница 17: ...umption Wattage 108 W typical Power output requirements Voltage 24 V DC 5 Current 6 25 A 150 W Physical Size 223 5 mm x 63 5 mm x 38 1 mm 8 8 in x 2 5 in x 1 5 in Weight 0 8 kg 1 8 lb Characteristic item Specification Display MTBF 50 000 hours Backlight MTBF 50 000 hours to 50 brightness with backlight on continuously Characteristic item Specification EMI shielding No emission of low level radiati...

Страница 18: ...ntal vertical Interface Digital Video In 2x DVI Rev 1 0 digital dual channel connector Display control brightness contrast DDC2B Display identification EDID read using DDC2B USB hub on stand N A USB uplink on display Universal Serial Bus Rev 2 0 1 uplink mini B USB port Display status Dual stack tricolor LEDs on back of unit MQSA Two color bottom facing LEDs on front of unit with push button activ...

Страница 19: ...umption Wattage 138 W maximum Power output requirements Voltage 24 V DC 5 Current 6 25 A 150 W Physical Size 223 5 mm x 63 5 mm x 38 1 mm 8 8 in x 2 5 in x 1 5 in Weight 0 8 kg 1 8 lb Characteristic item Specification Display MTBF 50 000 hours Backlight MTBF 50 000 hours to 50 brightness with backlight on continuously Characteristic item Specification EMI shielding No emission of low level radiati...

Страница 20: ...t only Dome S10 2x 2048 x 2560 non span mode Portrait 32 bit 10 4096 x 2560 horizontal span mode Landscape 32 bit 8 Windows 7 10 Windows XP Display Video Port DIN Connector Power Input Adapter Dome S3 DVI and DisplayPort 8 pin 12V 5 130 W BPC BPM130S12F02 with power switch Dome S3c DVI and DisplayPort 6 pin 24V 5 150 W BPC BPM150S24F05 with power switch Dome S10 DVI 6 pin 24V 5 150 W BPC BPM150S24...

Страница 21: ...E A red LED or combination of red LEDs indicates a hardware or software fault Contact Dome Technical Support for assistance LED A Action Sequence LED B Action Sequence Dark Initial power on Flashing yellow Initial power on Blink yellow Self test Solid yellow Power on self test Dark One 1 second after power on Flashing green Self test pass LED Status Description Solid green Functional link normal o...

Страница 22: ...nstall a more recent version The installation CD contains a file older than the one currently on your system The Confirm File Replace dialog box appears if the installation CD contains a file older than the one currently on the system Click No to the question Over write the newer file Or click No to All Unable to set the maximum or native resolution of the display The function Hide all modes that ...

Страница 23: ...ure that the entire system complies with applicable electromagnetic compatibility EMC laws Warning to Users of Dome Sx Displays The Dome S3 Dome S3c and Dome S10 displays are Class A products In a domestic environment either of these products may cause radio interference in which case the user may be required to take adequate measures Radio transmitting equipment cellular phones etc shall not be u...

Страница 24: ... MEDDEV guidance available at the time of classification Because the display uses electrical energy and has no direct patient connections and by itself no medical utility the display is classified according to Rule 12 as an MDD Class I device component or accessory The MDD states that manufacturers of Class I medical devices or accessories shall satisfy the requirements in regard to design and man...

Страница 25: ...Imaging not residing in the European Economic Area EEA has a European representative NDS Surgical Imaging Nijverheidscentrum 28 2761 JP Zevenhuizen The Netherlands phone 31 180 63 43 56 fax 31 180 63 21 91 In the opinion of NDS Surgical Imaging registration required to put this device into commerce is the responsibility of the medical device system manufacturer and NDS Surgical Imaging supports th...

Страница 26: ...romagnetic compatibility requirements EN 55011 Limits and methods of measurements for radio interference characteristics of industrial scientific and medical equipment IEC 1000 3 2 Harmonic emissions IEC 1000 3 3 Voltage fluctuations flicker emissions IEC 1000 4 2 Electrostatic discharge requirements for industrial process measurement and control equipment IEC 1000 4 3 Radiated electromagnetic fie...

Страница 27: ...when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the ...

Страница 28: ...ulsory Certification regulating safety and EMC GB4943 2001 GB9254 2008 CB17625 1 2003 Class A Dome S3 Dome S3c and Dome S10 TÜV Rheinland GM Mark for medical products Voluntary Control Council for Interference by information technology equipment sold in Japan Class A Dome S3 Dome S3c and Dome S10 Class B Korea Certification ...

Страница 29: ... repair or replace the display at its sole discretion The displays must have been run at or below the CXtra default brightness setting as configured from the factory If within 5 years of initial purchase the maximum output of the Dome Ex Sx color display excluding the Dome E4c is determined by NDSsi to be less than 250 cd m NDSsi will repair or replace the display at its sole discretion The displa...

Страница 30: ...products purchased through a distributor reseller or medical device manufacturer other than NDSsi each an Intermediary where such Intermediary provides direct warranty service to its end user customers in connection with such product DISCLAIMER This limited product warranty sets forth your sole and exclusive remedy and NDSsi s sole and exclusive liability under the Standard Limited Warranty descri...

Страница 31: ...This warranty gives you specific legal rights You may have other rights which may vary from locality to locality Some localities do not allow limitations on implied warranties and or do not allow the exclusion of incidental or consequential damages so the above limitations might not apply to you WARRANTY SERVICE REPAIR RETURN US AND CANADA ONLY Our standard warranty service is Repair and Return Re...

Страница 32: ...ervice technician will evaluate the unit and confirm the failure description provided by the customer a If the found failure type is covered under warranty the repair parts labor and shipment back to the customer will be at no charge b If the found failure type is not covered under warranty NDSsi s then current evaluation fee will apply in addition to the cost of parts labor and the return shipmen...

Страница 33: ... its sole discretion to request pre payment for any nonwarranty repairs NPF evaluations and return shipping charges prior to return of the product to customer Any invoiced amount not paid when due shall be subject to a service charge equal to the lesser of one and one half percent 1 5 per month or the maximum rate permitted by law If NDSsi undertakes collection or enforcement efforts customer shal...

Страница 34: ...NDS Surgical Imaging LLC 5750 Hellyer Avenue San Jose CA 95138 1000 USA www ndssi com ...

Отзывы: