Page 14
Leak Sensor Advanced User Manual
Compatible Command Classes
Command Class
Notes
Association V2 (0x85)
Group 1
Group 1 is the “Lifeline” group, which can hold five members, typically
including the main Z-Wave controller. The Leak Sensor sends this group
a Notification Report and a Binary Sensor Report when water is detected
or removed. It also sends this group a Battery Report in reponse to Bat-
tery Get commands and a Locally Reset Notification upon local reset.
Group 2
The Leak Sensor sends a Basic Set command to Association Group 2 (or
the Control Group) to directly trigger devices (like a light, chime, etc.) in
response to a detected leak. Then, after the leak is no longer detected, a
BASIC_SET(0x00) command is sent to reset the device (e.g. turn off the
light.) The value of the Basic Set command (e.g. brightness of the lamp)
is configured using configuration parameter 7.
Group 3
Group 3 supports up to 5 members and the Leak Sensor sends it a NO-
TIFICATION_REPORT when water is detected or removed.
Group 4
Group 4 supports up to 5 members and the Leak Sensor sends it a SEN-
SOR_BINARY_REPORT when water is detected or removed.
Notification V4 (0x71)
The Leak Sensor sends a Notification Report whenever a leak is detect
-
ed or removed.
Returned Value:
00 00 00 FF 05 XX 00 00
V1 Alarm Type
: 00
(Unsupported)
V1 Alarm Level
: 00
(Unsupported)
Reserved
: 00
(Reserved)
Notification Status:
FF
(Unsolicited Reporting is Enabled)
Notification Type
: 05
(Water Alarm)
Event
:
Leak Detected
—02
(Water Leak Detected, Unknown Location)
Leak Removed
—00
(Event Inactive)
Sequence/Reserved/Event Parameters Length:
00
Notification Event Parameters
: 00
(No Event Parameters)
Configuration V1(0x70) See “Configuration Parameters” on page 15.
Table 5 - Command Classes Continued