Door/Window Sensor Advanced User Manual
“Configuration” Command Class Parameters
Table 9 -
Door/Window Sensor Configuration Parameters
Param
#
Size
Name
Available Values
Default
Value
06
The Door/Window Sensor can report temperature values in either Celsius or Fahrenheit, and
this parameter allows the user to decide which unit is used.
01
Temperature Units
00
(Temperature is Reported in Fahrenheit)
01
(Temperature is Reported in Celsius)
00
(Temperature
is Reported in
Fahrenheit)
07
This parameter sets the value sent by the Basic Set command to Association Group 2. The
Door/Window Sensor sends a Basic Set command to Association Group 2 both when the tamper
switch opens and closes (for more information, see “Group 2” on page 14.)
01
Basic Set Value (Group 2)
00
(0/Turn Off Device)
01 ~ 63
(0-99)
FF
(255/Turn On Device)
FF
(255/Turn On
Device)
08
This parameter sets the value sent by the Basic Set command to Association Group 4. The
Door/Window Sensor sends a Basic Set command to Association Group 4 when the door or window
opens (for more information, see “Group 4” on page 14.)
01
Basic Set Level (Group 4 Opening)
00
(0/Turn Off Device)
01 ~ 63
(0-99)
FF
(255/Turn On Device)
FF
(255/Turn On
Device)
09
This parameter sets the value sent by the Basic Set command to Association Group 4. The
Door/Window Sensor sends a Basic Set command to Association Group 4 when the door or window
closes (for more information, see “Group 4” on page 14.)
01
Basic Set Level (Group 4 Closing)
00
(0/Turn Off Device)
01 ~ 63
(0-99)
FF
(255/Turn On Device)
00
(0/Turn Off
Device)