background image

 

 

[email protected]

 

www.dompneumatics.com 

Couplings.

 

Vibration  may  cause  failure  if  a  quick  change  coupling  is  connected  directly  to  the  tool.  To 
overcome this, connect a leader hose to the tool. A quick change coupling may then be used to 
connect the leader hose to the air line recoil hose. 

 

OPERATING INSTRUCTIONS: 

WARNING: Ensure you have read, understood and apply safety instructions before use. 
ASSEMBLY 
1. The Dom angle grinder comes with a handle and two spanners. 
2. The handle screws into the left-hand side of the head. 
3.  Remove  the  disc  locking  flange  nut  from  the  grinder  spindle.  Use  the  spanners  supplied  to 
hold the spindle and loosen/tighten the lock nut. 
4. Fit the grinding disc over the spindle (with the protruding side downwards) and retain it with                     
the flange nut. Use only discs with speed ratings equal to, or higher than, the speed rating of the 
grinder. 
5. Connect air supply to grinder and squeeze the control valve lever to check that the grinder is 
working correctly. 

OPERATING 

 

Do not apply excessive pressure, let the grinder do the work for you. Start the grinder and bring 
the disc to the work surface evenly and slowly. Move the grinder back and forth in overlapping 
areas.  Remove  the  grinding  disc  from  the  work  surface  before  stopping  the  grinder.  Regularly 
check the condition of the disc and always change if  worn, cracked or otherwise damaged. DO 
NOT run the grinder off the work piece for extended periods as this will shorten the life of  the 
bearings. 
 

MAINTANANCE : 

WARNING:  Disconnect  the  tool  from  air  supply  before  changing  the  disc,  servicing  or 
performing maintenance. Replace or repair damaged parts. 
1. Lubricate the tool daily with a few drops of no10 oil. 
2. Clean the grinder after use and change the disc when worn or damaged. 
3. Loss of power or erratic action may be due to the following. 
a) Excessive drain on the air supply. Moisture or restriction in the air line. Incorrect size or type 
of hose connectors. To remedy check the air supply and follow instructions. 
4. When not in use, disconnect from air supply, clean grinder and store in a safe.  

 

Отзывы: