USER MANUAL
STM 431J – Scavenger Transmitter Module
© 2017 EnOcean | www.enocean.com
STM 431J User Manual | v2.0 | Nov 2017 | Page 25/ 34
(current for external sensor circuits not included)
Calculations are performed on the basis of electric charges because of the internal linear
voltage regulator of the module. Energy consumption varies with voltage of the energy
storage while consumption of electric charge is constant.
From these values the following typical performance parameters at room temperature have
been calculated:
Wake
cycle
[s]
Transmit
interval
Operation Time
in darkness [h]
when storage
fully charged
Required reload
time [h] at 200
lux within 24 h
for continuous
operation
24 h operation
after 6 h
illumination
at x lux
Illumina-
tion level
in lux for
continuous
operation
Current
in µA
required
for con-
tinuous
operation
1
1
0.5
storage too small
storage too small
5220
130.5
1
10
1.7
storage too small
storage too small
1620
40.5
1
100
2.1
storage too small
storage too small
1250
31.3
10
1
5.1
storage too small
storage too small
540
13.5
10
10
16
21
storage too small
175
4.4
10
100
20
16.8
storage too small
140
3.5
100
1
43
7.8
260
65
1.6
100
10
98
3.6
120
30
0.8
100
100
112
3
100
25
0.6
Below is with secure mode enabled.
Wake
cyc-
le[s]
Transmit
interval
Operation Time
in darkness [h]
when storage
fully charged
Required reload
time [h] at 200
lux within 24 h
for continuous
operation
24h operation
after 6h illumi-
nation
at x lux
Illumina-
tion level
in lux for
continuous
operation
Current
in μA
required
for con-
tinuous
operation
1
1
0,4
Storage too small
Storage too small
7791
175
1
10
1,6
Storage too small
Storage too small
1991
45
1
100
2,2
Storage too small
Storage too small
1411
32
10
1
4
Storage too small
Storage too small
791
17,80
10
10
15
25
Storage too small
211
4,75
10
100
20
18
Storage too small
153
3,45
100
1
34
11
364
91
2,05
100
10
93
4
132
33
0,75
100
100
113
3
109
27
0,61
Assumptions:
Internal storage PAS614L-VL3 (after several days of operation at good illumination
level) with 0.25 F, Umax=3.2 V, Umin=2.2 V, T=25 °C
Consumption: Transmit cycle 100 µC, measurement cycle 30 µC
Pre-installed solar cell ECS 300, operating values 3 V and 5 µA @ 200 lux fluorescent
light
Current proportional to illumination level (not true at very low levels!)