background image

4

  

Advanced Features

 

Specifications

IP Rating: IP64
Temperature Rating: -40C to 70C / -40F to 158F
Size: 7 1/2in. x 7 3/4in. x 3 5/8in.  •  Weight: 1 ¾ lbs.
Housing: ABS  •  Face Plate Material: ABS
Operating Voltage: 6-24 AC/DC
Output relays: 1A

Channel

1

Add Guest Code

Access Code

1 2 3 4

3 #

The Guest Code is a one-time use access code. Once used, the number will 
be cleared from memory.

Channel

1

Add Access Toggle Code

Resetting the Keypad and Master Code

Toggle Code

1 2 3 4

4 #

NOTE: 

TOGGLE MODE ONLY FOR USE WHEN KEYPAD IS HARD WIRED.

 

Entering Access Toggle Code will toggle the keypad to continuously activate. 
Entering the code again will toggle the keypad off. Dip switch #6 on the circuit 
board needs to be in the off position in order for this mode to work.

Locate the red 

Master Reset Button

 

on the circuit board.

 
1.  

Remove the battery

 or eliminate the power source to the 

keypad.  Wait 30 seconds for the keypad to completely power off.

 
2.  Press and hold the 

Master Reset Button

.

 
3.  While holding the 

Button

, reconnect the battery or power 

source to the keypad.

 
4. Continue to hold to 

Button

 until the keypad beeps 3 times.  

This indicates that the Master Code has been reset to 

1234.

Содержание DOL1000-MF

Страница 1: ...1 Terminal Guide 2 Module Installation 3 Programming Guide 4 Advanced Features DOL1000 MF Keypad USER MANUAL VIDEO INSTRUCTIONAL...

Страница 2: ...1 Terminal Guide V V NO NC 6 24 VAC DC COM RF1 6 VDC BATTERY MASTER RESET BUTTON...

Страница 3: ...that requires a constant flow of electricity to function properly Example Magnetic locks receivers etc BATTERY 6VDC If deciding to power the DOL1000 MF with a battery then connect the battery to thes...

Страница 4: ...SOUND 2 LED 3 LIGHTS 4 Not used 5 Not used 6 WIRELESS MODE a Switching this dip switch to off will enable the toggle gate feature and switching to the on position will disable the toggle gate feature...

Страница 5: ...that connect to normally open normally closed STEP 3 Install the 433 MHz Module to the keypad board IMPORTANT Be sure to connect the power source to the correct terminals The battery terminals and th...

Страница 6: ...eceiver STEP 7 Install the module Add Access Codes New Access Code Channel NOTE Default Master Code 1 2 3 4 1 2 3 4 1 1 1 Remove Access Codes Access Code to Delete 1 2 3 4 2 New Master Code 2 Use Chan...

Страница 7: ...FOR USE WHEN KEYPAD IS HARD WIRED Entering Access Toggle Code will toggle the keypad to continuously activate Entering the code again will toggle the keypad off Dip switch 6 on the circuit board need...

Страница 8: ...ITY OR WARRANTY OF FITNESS FOR A PARTICU LAR PURPOSE BUYER MAKES NO RELIANCE ON ANY REPRESENTATION OF TRANSMITTER SOLUTIONS EXPRESS OR IMPLIED WITH REGARD TO THE GOODS AND ACCEPTS THEM AS IS WHERE IS...

Отзывы: