4
Advanced Features
Specifications
IP Rating: IP64
Temperature Rating: -40C to 70C / -40F to 158F
Size: 7 1/2in. x 7 3/4in. x 3 5/8in. • Weight: 1 ¾ lbs.
Housing: ABS • Face Plate Material: ABS
Operating Voltage: 6-24 AC/DC
Output relays: 1A
Channel
1
Add Guest Code
Access Code
1 2 3 4
3 #
The Guest Code is a one-time use access code. Once used, the number will
be cleared from memory.
Channel
1
Add Access Toggle Code
Resetting the Keypad and Master Code
Toggle Code
1 2 3 4
4 #
NOTE:
TOGGLE MODE ONLY FOR USE WHEN KEYPAD IS HARD WIRED.
Entering Access Toggle Code will toggle the keypad to continuously activate.
Entering the code again will toggle the keypad off. Dip switch #6 on the circuit
board needs to be in the off position in order for this mode to work.
Locate the red
Master Reset Button
on the circuit board.
1.
Remove the battery
or eliminate the power source to the
keypad. Wait 30 seconds for the keypad to completely power off.
2. Press and hold the
Master Reset Button
.
3. While holding the
Button
, reconnect the battery or power
source to the keypad.
4. Continue to hold to
Button
until the keypad beeps 3 times.
This indicates that the Master Code has been reset to
1234.