background image

6

 1

 2

 3

 4

 5

 6

 7

 8

 9

10

11

Key

14

15

16

17

18

19

20

21

22

23

24

Blower housing - Upper

Motor rubber - 

 

Large

Motor

Motor rubber - 

Small

Blower housing - 

Below

Heater assembly

Α

ir

 

outlet

Α

ir outlet bracket

Circuit Board Module

Description

LED assembly

Sensor 

module

Insulation 

Mylar shield with LNG marked

Cable clamp

Terminal block

Cover

Cable protector

Security hex screw (2 reqd.)

L-Wrench

Base plate

Grounding screw

Key

Description

Operating Instructions and Parts Manual 

Hand Dryer

Parts Diagram

Parts list

Surface-mounted high speed hand dryer 

4

15

18

16

17

24

20

23

19

21

5

6

7

8

9

10

11

13

12

25

22

14

25

Rubber grommet - Base 

(4 reqd.)

3

2

1

HEPA Filter

HEPA Filter box

HEPA Filter box - gasket

12

Sensor bracket

13

Содержание BC2009

Страница 1: ...BC2009 Hand Dryer ...

Страница 2: ...Adjustable by Owner m s adjustable 95 115 325 500 W 22000 29000 r p m Adjustable Brush Type Dual Ball Bearings Auto Resetting Thermostat turns unit off at 95 C 203 F Range Adjustable by Owner 325 500 W Auto Resetting Thermostat turns unit off at 85 C 185 F Thermal fuse cuts unit off at 142 C 288 F Less than 15 seconds Less than 0 5 W Infrared Automatic self adjusting Standard 170 20 mm Adjustable ...

Страница 3: ...d to the dryer s backplate Failure to properly ground unit could result in severe electrical shock and or death Type Y attachment If the power supply cord is damaged it must be replaced by the manufacturer or its service agent or a qualified person in order to avoid a hazard Disconnect the fixed wiring only in accordance with the wiring rules This appliance is not intended for use by persons inclu...

Страница 4: ... the green screw marked 1 Make sure power supply breaker is switched off Installation must be carried out in accordance with the current edition of the local wiring regulations code having jurisdiction Installation should be performed only by a qualified electrician 2 Place template against wall at desired height see mounting height recommendations and mark locations of 4 mounting holes and wire s...

Страница 5: ...nd dryer Cleaning and Maintenance Every six months is recommended Recommended mounting heights Men Women Children 4 7 years Children 8 10 years Children 11 13 years Children 14 16 years Wheelchair 1194 mm 889 mm 991 mm 1092 mm 1194 mm 1016 mm 1270 mm Unit should be mounted to give no less than 300 mm clearance from the bottom of the unit to the nearest surface below from bottom edge of dryer above...

Страница 6: ...Actions for In Service Failures If the dryer will not run The IR sensor only sees close range objects The dryer only blows cold air during a full cycle Ensure that there is no obstruction on or in front of the IR sensor Clean any dirt or debris off the sensor lens If problem persists replace sensor and CBM First ensure that the breaker supplying the dryer is operational If it is disconnect the pow...

Страница 7: ...ule Insulation Mylar shield with LNG marked Cable clamp Terminal block Cover Cable protector Security hex screw 2 reqd L Wrench Base plate Grounding screw Key Description Operating Instructions and Parts Manual Hand Dryer Parts Diagram Parts list Surface mounted high speed hand dryer 4 15 18 16 17 24 20 23 19 21 5 6 7 8 9 10 11 13 12 25 22 14 25 Rubber grommet Base 4 reqd 3 2 1 HEPA Filter HEPA Fi...

Отзывы: