  Connection Example

T3

L

N

A1

A1

A1

A1

L

N

23

13

A2

A2

A2

A2

QX1

QX2

QX2

QX1

24

14

QX1

QX2

S1

S1

S4

S2

S2

S3

S3

S3

S2

S4

S4

S1

GND

1

GND

1

GND

1

GND

2

GND

2

GND

2

GND

2

GND

2

GND

2

S5

S5

S8

S6

S6

S7

S7

S7

S6

S8

S8

S5

GND

1

GND

1

GND

1

RP5994

RP5995

RP5995

Indication EH5994

Ra

Ra

Ra

Ra

*)

*)

*)

*)

B

B

B

B

A

A

A

A

Rb

Rb

Rb

Rb

Sh

Sh

Sh

Sh

CA

CA

T1 External rest button , function according to configuration

with bridge X1/X2 closed circuit operation

T3 External rest button , function according configuration

*) both ends of the bus have to be terminated

on the first and on the last module by inserting
the links A/Ra and B/Rb

M9907

T1

T2

Содержание RP 5994

Страница 1: ...for audible alarm and common alarm on request Reset buttons for audible alarm common alarm and single alarm Connection of remote reset button Function according to setting Display unit EH 5994 EH 5995 Exchangable front label for individual legending As option galvanic separated RS458 bus Protection degree for front side IP 64 Enclosure for flush mounting 96 x 96 mm Display unit EH 5994 8 fault sig...

Страница 2: ... operation alarm 2 open circuit operation alarm 1 closed circuit operation alarm 2 closed circuit operation LED 1 LED 2 LED CA relay audible alarm off on reset audible alarm relay common alarm M9902 alarm 1 open circuit operation alarm 1 open circuit operation alarm 1 closed circuit operation alarm 1 closed circuit operation LED 1 LED 2 LED CA relay audible alarm reset common alarm off on reset au...

Страница 3: ...y the module Lamp Test Pressing the pushbuttons QH and QCA simultaneously during normal operation will force a lamp test function LT During lamp test all fault signal LEDs are switched on The lamp test function can also be operated by bridging the terminal QX1 QX2 connection remote reset if this function is selected on switch Set for QX1 QX2 Fault Diagnostics To indicate failures of the system the...

Страница 4: ...ibration resistance 0 35 mm amplitude frequency 10 55 Hz IEC EN 60 068 2 6 Climate resistance 20 055 04 IEC EN 60 068 1 Terminal designation EN 50 005 Wire connection DIN 46 228 1 2 3 4 fixed screw terminal S 0 2 4 mm2 solid or 0 2 1 5 mm2 stranded wire with sleeve plug in screw terminal PS 0 1 2 5 mm2 solid or 0 1 1 5 mm2 stranded wire with sleeve plug in cage clamp terminals PC 0 2 2 5 mm2 solid...

Страница 5: ...7 S7 S6 S8 S8 S5 GND 1 GND 1 GND 1 RP5994 RP5995 RP5995 Indication EH5994 Ra Ra Ra Ra B B B B A A A A Rb Rb Rb Rb Sh Sh Sh Sh CA CA T1 External rest button function according to configuration with bridge X1 X2 closed circuit operation T3 External rest button function according configuration both ends of the bus have to be terminated on the first and on the last module by inserting the links A Ra a...

Страница 6: ...6 27 10 15 en 605 E DOLD SÖHNE KG D 78114 Furtwangen e mail dold relays dold com internet http www dold com POBox1251 Telephone 49 7723 654 0 Telefax 49 77 23 654 356 ...

Отзывы: