Installation / Monitoring Technique
INFOMASTER
B Common Alarm System, Bus Connection
New- / First- /Common Signal Annunciator
RP 5994, RP 5995
New- / First- /Common Signal Annunciator RP 5994, RP 5995
•
Fast localisation of failures and their causes
•
Reduction of standstill times in production
•
Adjustable operating modes:
New- / First signal annunciator according to DIN 19 235,
common alarm annunciator manual reset / auto reset settable
•
Expandable from 8 to 88 fault signals
•
Open or closed circuit operation settable
•
Adjustable on delay for input signals 0 to 10 sec
•
Reset buttons for audible alarm and common alarm on front side
•
Connection for external reset of audible alarm, common alarm
and single alarm according to setting
•
Galvanic separation to bus RS485 (optional)
•
Accessories: buzzer RK 8832, display unit EH 5994, EH 5995
text display unit EH 5996, GMS-module RP 5810
•
Width: 70 mm
Base module RP 5994:
- 8 fault signal inputs with indicator LED on the unit
- One relay output each for audible alarm and common alarm
- Reset buttons for audible alarm, common alarm, and single alarm
- Connection of remote reset button. Function according to setting
Extension module RP 5995:
- 8 fault signal inputs with indicator LED on the unit
- One relay output each for audible alarm and common alarm (on request)
- Reset buttons for audible alarm, common alarm, and single alarm
- Connection of remote reset button. Function according to setting
Display unit EH 5994, EH 5995
•
Exchangable front label for individual legending
•
As option galvanic separated RS458 bus
•
Protection degree for front side IP 64
•
Enclosure for flush mounting 96 x 96 mm
•
Display unit EH 5994:
- 8 fault signal LEDs on the unit
- Reset buttons for audible alarm, common alarm and alarm signal
•
Display unit EH 5995:
- 8 fault signal LEDs on the unit
- Without reset buttons
0255005
Circuit Diagrams
RP 5994
RP 5995
M9383_a
S6
S8
QX1
13
23
S5
S7
GND
2
GND
2
QX2
14
24
A1 A2
Ra
A
S1
B
S2
S4
Rb
Sh
S3
GND
1
GND
1
13
23
CA
S1
S2
S3
S4
S5
S6
S7
S8
CA
14
24
M9521_a
QX1
GND
2
GND
2
QX2
A1 A2
Ra
A
S1
B
S2
S4
Rb
Sh
S3
GND
1
GND
1
CA
S1
S2
S3
S4
S5
S6
S7
S8
S6
S8
S5
S7
EH 5994
RP 5994
EH 5995
RP 5995
Approvals and Markings
Additional Information about this topic
•
General information for INFOMASTER
B see data sheet
INFOMASTER
B, System overview
•
Information about the additional text display unit
see data sheet EH 5996
•
Information about the additional GSM-module for alarm
and acknowledgement per SMS see data sheet RP 5810
Circuit Diagram
M9568_a
A1 A2
Ra
A
B
Rb
Sh
CA
S1
S2
S3
S4
S5
S6
S7
S8
EH 5994, EH 5995
All technical data in this list relate to the state at the moment of edition. We reserve the right for
technical improvements and changes at any time.