DOLD RP 5994 Скачать руководство пользователя страница 1

1

27.10.15 en / 605

 

Installation  / Monitoring Technique

 INFOMASTER

 

B Common Alarm System, Bus Connection 

  New- / First- /Common Signal Annunciator
  RP 5994, RP 5995

New- / First- /Common Signal Annunciator RP 5994, RP 5995

  Fast localisation of failures and their causes

  Reduction of standstill times in production

  Adjustable operating modes:

  New- / First signal annunciator according to DIN 19 235, 
  common alarm annunciator manual reset / auto reset settable

  Expandable from 8 to 88 fault signals

  Open or closed circuit operation settable 

  Adjustable on delay for input signals 0 to 10 sec

  Reset buttons for audible alarm and common alarm on front side

  Connection for external reset of audible alarm, common alarm  

  and single alarm according to setting

  Galvanic separation to bus RS485 (optional)

  Accessories: buzzer RK 8832, display unit EH 5994, EH 5995

   

            text display unit EH 5996, GMS-module RP 5810

  Width: 70 mm

Base module RP 5994:

 

-  8 fault signal inputs with indicator LED on the unit

 - One relay output each for audible alarm and common alarm
  -  Reset buttons for audible alarm, common alarm, and single alarm
  -  Connection of remote reset button. Function  according to setting

Extension module RP 5995:

 - 8 fault signal inputs with indicator LED on the unit
 - One relay output each for audible alarm and common alarm (on request)
 -  Reset buttons for audible alarm, common alarm, and single alarm
  -  Connection of remote reset button. Function  according to setting

Display unit EH 5994, EH 5995

  Exchangable front label for individual legending

  As option galvanic separated RS458 bus

  Protection degree for front side IP 64

  Enclosure for flush mounting 96 x 96 mm

 

Display unit EH 5994:

  -  8 fault signal LEDs on the unit
  -  Reset buttons for audible alarm, common alarm and alarm signal

 

Display unit EH 5995:

  -  8 fault signal LEDs on the unit
  -  Without reset buttons

0255005

 

Circuit Diagrams

RP 5994

RP 5995

M9383_a

S6

S8

QX1

13

23

S5

S7

GND

2

GND

2

QX2

14

24

A1 A2

Ra

A

S1

B

S2

S4

Rb

Sh

S3

GND

1

GND

1

13

23

CA

S1

S2

S3

S4

S5

S6

S7

S8

CA

14

24

M9521_a

QX1

GND

2

GND

2

QX2

A1 A2

Ra

A

S1

B

S2

S4

Rb

Sh

S3

GND

1

GND

1

CA

S1

S2

S3

S4

S5

S6

S7

S8

S6

S8

S5

S7

EH 5994

RP 5994

EH 5995

RP 5995

 

Approvals and Markings

  Additional Information about this topic

  General information for INFOMASTER

 

B see data sheet 

 INFOMASTER

 

B, System overview

  Information about the additional text display unit 

  see data sheet EH 5996 

  Information about the additional GSM-module for alarm

  and acknowledgement per SMS see data sheet RP 5810

 

Circuit Diagram

M9568_a

A1 A2

Ra

A

B

Rb

Sh

CA

S1

S2

S3

S4

S5

S6

S7

S8

EH 5994, EH 5995

All technical data in this list relate to the state at the moment of edition. We reserve the right for 
technical improvements and changes at any time.

Содержание RP 5994

Страница 1: ...for audible alarm and common alarm on request Reset buttons for audible alarm common alarm and single alarm Connection of remote reset button Function according to setting Display unit EH 5994 EH 5995 Exchangable front label for individual legending As option galvanic separated RS458 bus Protection degree for front side IP 64 Enclosure for flush mounting 96 x 96 mm Display unit EH 5994 8 fault sig...

Страница 2: ... operation alarm 2 open circuit operation alarm 1 closed circuit operation alarm 2 closed circuit operation LED 1 LED 2 LED CA relay audible alarm off on reset audible alarm relay common alarm M9902 alarm 1 open circuit operation alarm 1 open circuit operation alarm 1 closed circuit operation alarm 1 closed circuit operation LED 1 LED 2 LED CA relay audible alarm reset common alarm off on reset au...

Страница 3: ...y the module Lamp Test Pressing the pushbuttons QH and QCA simultaneously during normal operation will force a lamp test function LT During lamp test all fault signal LEDs are switched on The lamp test function can also be operated by bridging the terminal QX1 QX2 connection remote reset if this function is selected on switch Set for QX1 QX2 Fault Diagnostics To indicate failures of the system the...

Страница 4: ...ibration resistance 0 35 mm amplitude frequency 10 55 Hz IEC EN 60 068 2 6 Climate resistance 20 055 04 IEC EN 60 068 1 Terminal designation EN 50 005 Wire connection DIN 46 228 1 2 3 4 fixed screw terminal S 0 2 4 mm2 solid or 0 2 1 5 mm2 stranded wire with sleeve plug in screw terminal PS 0 1 2 5 mm2 solid or 0 1 1 5 mm2 stranded wire with sleeve plug in cage clamp terminals PC 0 2 2 5 mm2 solid...

Страница 5: ...7 S7 S6 S8 S8 S5 GND 1 GND 1 GND 1 RP5994 RP5995 RP5995 Indication EH5994 Ra Ra Ra Ra B B B B A A A A Rb Rb Rb Rb Sh Sh Sh Sh CA CA T1 External rest button function according to configuration with bridge X1 X2 closed circuit operation T3 External rest button function according configuration both ends of the bus have to be terminated on the first and on the last module by inserting the links A Ra a...

Страница 6: ...6 27 10 15 en 605 E DOLD SÖHNE KG D 78114 Furtwangen e mail dold relays dold com internet http www dold com POBox1251 Telephone 49 7723 654 0 Telefax 49 77 23 654 356 ...

Отзывы: