Dolby Laboratories DolbyRemote DP569 Скачать руководство пользователя страница 19

DolbyRemote Installation and Operation

Dolby Digital Parameters

4-3

designated as two numbers, A/B, with A indicating the number of front channels, and
B indicating the number of rear (surround) channels.

The following table lists all eight modes and defines which input channels are used
for encoding based on the selected mode. Channel names are designated as follows:
Left (L), Right (R), Center (C), Left Surround (Ls), and Right Surround (Rs). Note
that the Ls channel is the surround source for modes having a single surround channel
(2/1, 3/1). In the case of mode 1+1, two completely independent program channels
can be sourced from the L and R inputs (dual mono) and encoded into the output
bitstream. 1+1 mode is not suitable for DVD or DTV applications.

The 

Audio Coding Mode

 options available for the DP567 are 1+1 Dual Mono, 1/0

Mono and 2/0 Stereo.

Table 4-1 

Audio Coding Modes

Audio Coding Mode

Encoded Channels

1+1 (Dual Mono)

L, R

1/0 (Mono)

C

2/0 (Stereo)

L, R

3/0

L, C, R

2/1

L, R, Ls

3/1

L, C, R, Ls

2/2

L, R, Ls, Rs

3/2

L, C, R, Ls, Rs

4.1.5 LFE 

Enable

LFE Enable

 determines whether the low frequency effects channel is enabled. This

is dependent on the setting of the audio coding mode and is only active with coding
modes greater than two channels. This option is also not available on the DP567.

4.1.6 Bitstream 

Mode

Bitstream Mode

 is an informational parameter that indicates the data information

service of the encoded Dolby Digital bitstream. It does not affect internal Dolby
Digital encoding.

4.1.7 Dialog 

Normalization

Dialog Normalization 

allows the user to set the value of 

dialnorm

,

 a parameter that

tells the decoder how much the average dialogue level of the encoded audio is below
digital full scale. The decoder uses this to normalize the replay level. This means

Содержание DolbyRemote DP569

Страница 1: ...DolbyRemote Installation and Operation P N 91659 Issue 1...

Страница 2: ...ile 86 21 6418 1013 LIMITATION OF LIABILITY It is understood and agreed that Dolby Laboratories liability whether in contract in tort under any war ranty in negligence or otherwise shall not exceed th...

Страница 3: ...ces 2 4 Chapter 3 Disk Files 3 1 3 1 Saving and Restoring Configurations 3 1 3 2 Exporting Configurations 3 1 Chapter 4 Dolby Digital Parameters 4 1 4 1 Audio Service Parameters 4 1 4 1 1 Input Meters...

Страница 4: ...Bits 4 13 4 5 4 Test Tone Generation 4 13 4 5 5 Stream Number 4 14 4 6 Reference Input 4 14 4 6 1 Reference Input 4 14 4 6 2 Reference Input Subcode Status Bits 4 15 4 7 Presets 4 15 4 7 1 Recall 4 1...

Страница 5: ...2 1 2 2 Device Off Line 2 2 2 3 DolbyRemote Window 2 3 2 4 Two Encoders Controlled 2 3 4 1 Audio Service Parameters 4 1 4 2 Preprocessing Tab 4 6 4 3 Bitstream Info Tab 4 8 4 4 Dual Mono Tab 4 10 4 5...

Страница 6: ......

Страница 7: ...he presence of the encoder hardware Save a unit configuration in a file on a PC Restore the unit s configuration from a saved DolbyRemote file Export an encoder s configuration in human readable form...

Страница 8: ...e computer 3 Click Start and Run 4 Browse to the DolbyRemote diskette Select setup exe and click OK 5 Please read the Limitation of Liability and Welcome screens before proceeding with the installatio...

Страница 9: ...on a computer five devices may be controlled with a single instance of the DolbyRemote application A single RS 485 computer port may connect to several devices provided the devices all have an RS 485...

Страница 10: ......

Страница 11: ...be controlled Choices are DP561 DP567 or DP569 2 1 2 Communications These settings control the communication parameters for the DolbyRemote application The corresponding parameters must be set for th...

Страница 12: ...evice Type only the Port parameter may be set Baud and Address are fixed at 38 400 and 9080 respectively 2 1 3 Off Line The DolbyRemote application may be used off line without the presence of an enco...

Страница 13: ...several Dolby professional audio products If you have more than one device you may control them all from a single instance of the DolbyRemote application hardware permitting To add additional encoders...

Страница 14: ...DolbyRemote Installation and Operation Establishing Communication 2 4 2 3 Removing Devices To remove or discontinue the remote control of a device click Close or select File Close Device...

Страница 15: ...each different encoder type has some unit specific commands The DolbyRemote file format is different from the Ac3Enc original DP561 remote file format so these files may not be opened in the DolbyRem...

Страница 16: ...DolbyRemote Installation and Operation...

Страница 17: ...as an introduction for new users rather than the full explanation that will be required Detailed information about each encoder setting can be found in the relevant encoder user s manual or in the pag...

Страница 18: ...Ref In input Internal 48 44 1 or 32 kHz always valid when selected Dig In 1 2 is the only input that may function as both an Input Source and Clock Source simultaneously The clock source setting also...

Страница 19: ...able for the DP567 are 1 1 Dual Mono 1 0 Mono and 2 0 Stereo Table 4 1 Audio Coding Modes Audio Coding Mode Encoded Channels 1 1 Dual Mono L R 1 0 Mono C 2 0 Stereo L R 3 0 L C R 2 1 L R Ls 3 1 L C R...

Страница 20: ...d to route the output of a secondary standby encoder to the switched audio output of the primary encoder To enable this function the Bypass In connector of the primary encoder must be linked to the Ma...

Страница 21: ...e 170 ms Then the input changes to 44 1 kHz At 44 1 kHz the smallest legal coding delay is 195 ms The DP569 will switch to a 195ms coding delay The actual coding delay will display 195 ms while the re...

Страница 22: ...15 s pre emphasis has been applied The state of Deemphasis and the channel status bit will be ignored whenever pre encoded bitstreams are being received Pass Through mode is active DC Highpass Filter...

Страница 23: ...a decoder on how to reduce the dynamic range for others For example some people will want a reduced dynamic range for late night listening or because they have a smaller replay system The choice of Co...

Страница 24: ...de meters show the current value of the cut and boost words being included in the Dolby Digital bitstream Red shows compression cut and green shows boost calibrated in dB Line mode represents a two ch...

Страница 25: ...e Copyright Bit Copyright Bit is an informational parameter that indicates whether or not the Dolby Digital bitstream is protected by copyright Original Bitstream Original Bitstream is an informationa...

Страница 26: ...4 4 2 Dynamic Range Compression Input Level Line Mode and RF Mode Input Level Line Mode and RF Mode meters for channel two when in 1 1 Coding Mode only The Compression Characteristic is the same as t...

Страница 27: ...rate of the digital input channels Integrity Integrity shows the data integrity of the digital input channels Format Format is a control parameter that allows you to choose the format of the data rece...

Страница 28: ...ws you to select between analog and digital audio input sources Only one input source can be active at a time This parameter is not available on the DP569 Channel Assignment Channel Assignment allows...

Страница 29: ...rwrites the selected output channel with the internally encoded or pre encoded bitstream but passes through the reference PCM signal on the opposite channel without modification Autodetect and Pass Th...

Страница 30: ...the input stream number for a pre encoded signal present at the reference input Output Output defines the stream number for the Dolby Digital output of the encoding process The default is zero If mul...

Страница 31: ...dio bit as indicated in the subcode of the reference input signal 4 7 Presets Presets 29 through 32 are factory defaults and cannot be overwritten Figure 4 8 Presets Tab 4 7 1 Recall Click on any of t...

Страница 32: ...ough 32 are factory defaults and cannot be overwritten Name Enter a name if desired for the preset Save Current Configuration Click this button to save the current configuration in the selected preset...

Страница 33: ...ams of a specific length and position in time primarily for DVD authoring The start and stop times are specified in the format HH MM SS FF ssss where HH hours 00 to 23 MM minutes 00 to 59 SS seconds 0...

Страница 34: ...elected a start time and a preset you can t change the start time If you want to change the start time you must follow this procedure 1 Select None in the Preset Pending field 2 Enter the new Start Ti...

Страница 35: ...de press shift C on the keyboard The VGA screen should show that the unit is in remote mode It is possible to program the DP561 to always boot up into remote mode Consult the product manual for detail...

Страница 36: ...lable at our web site www dolby com Dolby Laboratories can be contacted at the following addresses Dolby Laboratories Inc 100 Potrero Avenue San Francisco CA 94103 4813 USA Main 415 558 0200 Fax 415 8...

Отзывы: