DolbyRemote Installation and Operation
Dolby Digital Parameters
4-2
4.1.2 Data
Rate
Data Rate
determines the bit rate of the encoded Dolby Digital bitstream. All data
rate options are allowed, however, selection of the data rate is dependent on the
settings of the
Audio Coding Mode
,
Sample Rate
and
Auxiliary Data
parameters.
Certain low data rates may not be supported in all channel modes. For example rates
56, 64 and 80 kbps are only supported in 1/0 channel modes.
4.1.3 Clock
Source
Clock Source
is a parameter that specifies the reference clock source for the encoding
process as well as the reference for the output signal. The encoder will not produce a
valid output signal if a clock source is not present. A green indicator is present for a
valid source, a red indicator will be present for an invalid source. There are three
types of clock sources:
•
Digital Input
: a valid AES/EBU signal must be present at the
Dig In 1/2
input.
•
Ref In
: a valid AES/EBU signal must be present at the
Ref In
input.
•
Internal
(48, 44.1 or 32 kHz): always valid when selected.
Dig In 1/2
is the only input that may function as both an
Input Source
and
Clock
Source
simultaneously.
The clock source setting also controls the state of the internal sample rate conversion
(SRC). SRC is disabled for the
Digital Input
and
Ref In - SRC Off
settings. SRC is
enabled for the
Ref In - SRC On
and
Internal
clock source settings.
There are some restrictions on the clock source selection that are enforced by the
DolbyRemote application:
•
If
Ref In-SRC On
or an
Internal
clock source is selected the current
Input
Format
must be PCM.
•
If
Digital Input
or an
Internal
clock source is selected, the
Multiplex Mode
must be disabled.
•
If
Internal 32 kHz
is selected the output mode must be
Professional 32-bit
or the
Data Rate
must be less than 448 kbps.
•
If an internal clock source is selected, the frequency must be consistent with
the coding delay and the auxiliary data input selection. See the DP567/DP569
user’s manual for details.
4.1.4 Audio
Coding
Mode
Audio Coding Mode
defines the number of full-bandwidth audio channels within the
encoded bitstream and also indicates the channel format. The audio coding mode is
Содержание DolbyRemote DP569