DOL 16 0-50/1000 LUX 0-10V
7 Technical data
Unit
Output 1
Output 2
Measurement range
Lux
0-50
0-1000
Accuracy
2-50 Lux +/- 4%
at 0 – 40
o
C (32 – 104
o
F)
25-1000 Lux +/- 8%
at 0 – 40
o
C (32 – 104
o
F)
Output signal (l
out
)
0.2 V / 1 Lux
0.1 V / 10 Lux
Common
Time constant
Sec.
Typ. 2
Max. 15
Supply voltage (V
supply
)
V DC
11 - 30
Supply current
mA
12 no load
55 max. load
Load
Ω
>500 – 10M
Recommended load
kΩ
>100
Output current
mA
20 per output (current limited)
Output impedance
Ω
<1
Temperature, operation
o
C (
o
F)
-40 – 60 (-40 – 140)
IP classification
IP (NEMA)
67 (6)
Cable
2 m (6.6 feet) 4 x 0.33 mm
2
(22 AWG)
Cable connection
(only M12 variant)
M12 female connector with 2 m (6.6 feet) 4 x 0.33 mm2
(22AWG) cable
Max. cable length
m
100 0,82 mm
2
(328 feet 18 AWG)
Shipping weight
g (oz)
150 (5.3)
Measure, shipment
mm (inch)
275 x 200 x 20 (11 x 8 x 0.8)
7.1 Dimensioned sketch
Dimensions In mm (inch).