Technical User Guide
DOL 16 0-50/1000 LUX 0-10V
3
If ceiling mounting is not possible or not wanted, the sensor can be hung in the
cable 1-2 meters above the animals. If this type of mounting is used, the sensor
must be cleaned daily with a dry cloth.
When removing variant with M12 connector, the included plug must be mounted.
3 LED indication
LED indication
Sensor status
GREEN ON
Operation OK
RED ON
Connection error
Load < 500 Ω
RED flashes
Sensor defective
Over/under voltage alarm
Overload
4 Connection
Installation, servicing and troubleshooting of all electrical equipment must be carried out by quali-
fied personnel in compliance with the applicable national and international standard EN 60204-1
and any other EU standards that are applicable in Europe.
+V (Brown)
GND (Blue)
(Black)
(White)
Power
supply
11 - 30 V DC
0-1000 Lux
0-50 Lux
Figure 3: Figure 4: Connection.
If 1:1 compliance with the L 182/19-standard is desired, measurements according to the standard and an adap-
tation to the output of the DOL 16 sensor with the chosen placement must be carried out.