background image

Technical User Guide

DOL 20R

capacitive sensor

For other language variants of this document we refer to 

www.dol-sensors.com

 or

your local dealer.

dol-sensors a/s  – Agro Food Park 15  – DK-8200 Aarhus N  – T: +45 7217 5888  – F: +45 7217 5959  – www.dol-sensors.com

Содержание 20R

Страница 1: ...OL 20R capacitive sensor For other language variants of this document we refer to www dol sensors com or your local dealer dol sensors a s Agro Food Park 15 DK 8200 Aarhus N T 45 7217 5888 F 45 7217 5959 www dol sensors com ...

Страница 2: ...of dust and the impact of water on the detection area of the sensor including condensation If there is significant wear the sensor should be mounted behind a wear plate made of a suitable plastic material The sensor is not side sensitive but to avoid incorrect detection as a result of uncertainty with regard to mounting it is best to keep the sensor away from any metal components see the di mensio...

Страница 3: ...ed disconnection fixed delay or delay can be adjusted on the trimmer Delayed connection fixed delay or delay can be adjusted on the trimmer Sensitivity fixed distance or Distance can be adjusted on the trimmer MaxRun timer DOL 20R Settings on the trimmer Off Period 1 Period 2 5 Maintenance If the sensor is located in a particularly dirty environment it may be necessary to clean the area around the...

Страница 4: ...2 0 0 47 Hysteresis H 8 10 Mechanical Cable length m ft 2 6 5 Cable dimensions mm AWG 5x0 5 5x20 Frame for mounting sensor Included Environment Temperature operation C F 20 70 4 158 Temperature storage C F 30 80 22 176 Protection class IP NEMA 67 4 Approvals CE C UL Can be modified according to customer needs 6 1 Dimensions 604093 2022 08 17 en US Made in Denmark ...