background image

4

MN16022

MOUNTING POSITION DIAGRAMS -

QUANTIS UK RHB REDUCER

 

These mounting arrangements are for all output configurations 

and output shaft types. 
IMPORTANT! When ordering, please specify mounting position 

for correct oil quantity. In cases of mounting position other than 

shown here with regard to the oil quantity, please reference the 

Incline Mounting page in the Quantis Engineering Catalog, and 

contact Application Engineering.

NOTE: The oil volumes shown are approximate values and cannot 

be used to correctly set the reducer oil level - ALWAYS fill the 

reducer to the correct oil level plug and recheck in 1 week.

Oil Level

Ventilation

Oil Drain

A1 - Horizontal - Floor Mount

A

B

B

A

A2 - Vertical Wall Mount - Motor Shaft Up

NOTE: Shaded A2 mounting is not a recommended mounting 

position due to the weight of oil on the highspeed input seal.

B

A

A3 - Horizontal - Ceiling Mount

A

B

A4 - Vertical Wall Mount - Motor Shaft Down

B

A

A5 - Horizontal - Wall Mount

A

B

A6 - Horizontal - Wall Mount

Содержание Quantis Ultra Kleen

Страница 1: ...n Company Inc invoice be withheld awaiting claims adjustment The carrier not Dodge guarantees safe delivery If considerable damage or shortage has occurred and the situation is urgent contact the near...

Страница 2: ...omplex thickener and ISO 220 viscosity mineral oil base lubricant Use 15 pumps of grease for the first re greasing and 5 pumps of grease for subsequent re greasing Dodge Quantis Ultra Kleen RHB Reduce...

Страница 3: ...bricant Selection Table Ambient Temperature OilType ISO ViscosityGrade AvailableOils AvailableFoodGradeOils NSF H1 45 Fto105 F 7 Cto41 C MineralOil 460 ChevronFM460 10 Fto105 F 12 Cto41 C MineralOil 2...

Страница 4: ...Catalog and contact Application Engineering NOTE The oil volumes shown are approximate values and cannot be used to correctly set the reducer oil level ALWAYS fill the reducer to the correct oil level...

Страница 5: ...s on the reducer and drive motor to verify that the drive is correct for the intended loads speeds and power supply The gear reducer should be installed in a location that meets the following requirem...

Страница 6: ...he motor flange holes line up with the C Face adapter holes Check to be sure the motor conduit box grease fittings and condensate drains where fitted will be oriented as needed by the reducer mounting...

Страница 7: ...6 After the gearbox has been pulled completely onto the machine shaft firmly against the machine shaft s backing shoulder it must be locked in place with the retaining bolt tightened to the tightenin...

Страница 8: ...uld be 0 01 in for inch bore shafts Bold shaft diameters indicate standard shaft RS dimension is the minimum recommended shaft shoulder diameter Table6 MetricShaftsforStraightHollowBoreInstallation Di...