Again turn output hub to roll in the bearings. With a 
feeler or taper gage, measure the gap between the 
housing and the carrier, clockwise from and next to 
each screw. To determine the required shim 
thickness, take the average of the two feeler gage 
readings. Remove carrier and install the required 
shims. Note: Total shim thickness per carrier 
should not include more than .009" plastic shims 
and each plastic shim should be inserted between 
two metal shims. Place a 

1

/

8

" diameter bead of 

Dow Corning RTV732 sealant on the face around 
the I.D. of the end shim (sealant is to be between 
reducer housing and shim) and install carrier on 
reducer housing. Torque carrier bolts to value 
shown in Table 7. Output hub should have an axial 
end play of .001" to .003". 

7. 

Using the same procedure as in step 6, adjust the 
input shaft bearings, except the axial end play 
should be .002" to .004". 

Table 7 — Bolt Tightening Torque Values

 

Reducer 

Size 

Housing Bolts 

(in.-lbs.) 

Seal Carrier Bolts

(in.-lbs.) 

HXT305A 600 

204 

HXT405A 600 

360 

HXT505A 900 

360 

8. 

Apply sealant to the input shaft cover gasket and 
install input shaft cover in right-hand housing half. 
Install input and output seals. Extreme care should 
be used when installing seals to avoid damage due 
to contact with sharp edges on the input shaft or 
output hub. This danger of damage and consequent 
oil leakage can be decreased by covering all sharp 
edges with tape or paper prior to seal installation. Fill 
cavity between seal lips with grease. Seals should be 
pressed or tapped with a soft hammer evenly into 
place in the carrier applying pressure only on the 
outer edge of the seals. A slight oil leakage at the 
seals may be evident during initial running in but 
should disappear unless seals have been damaged. 

9. 

Install bushing back-up plate and snap rings. 

Содержание HXT305A

Страница 1: ...ric Company nor are the responsibility of Baldor Electric Company This unit and its associated equipment must be installed adjusted and maintained by qualified personnel who are familiar with the construction and operation of all equipment in the system and the potential hazards involved When risk to persons or property may be involved a holding device must be an integral part of the driven equipm...

Страница 2: ......

Страница 3: ...nput end of the reducer 5 Install torque arm fulcrum on a rigid support so that the torque arm will be approximately at right angles to the center line through the driven shaft and the torque arm anchor screw CHAR LYNN H S T AND 2000 SERIES 6B SPLINE MOTOR INSTALLATION Consult the local Char Lynn Motor dealer for hydraulic motor information WARNING To ensure that drive is not unexpectedly started ...

Страница 4: ...application engineering 20ºF to 22ºF use Mobil SHC 627 Above 125ºF use Mobil SHC 634 See page 8 for lubricant viscosity classification equivalents NOTE Pour point of lubricant selected should be at least 10ºF lower than expected minimum ambient starting temperature Special lubricants may be required for food and drug industry applications where contact with the product being manufactured may occur...

Страница 5: ...5 Note The two digit numbers are for reference only Order parts by the six digit numbers in the Parts List Each six digit number is a complete identification of the part or assembly ...

Страница 6: ...84 17 16 Bore 1 243260 244079 1 Bore 1 243262 244081 15 8 Bore 1 243264 244083 111 16 Bore 1 243268 244085 1 Bore 1 243266 244087 17 8 Bore 1 243270 244089 245084 84 BUSHING 115 16 Bore 1 243272 244093 245086 ASSEMBLY 2 Bore 1 243274 244095 245088 21 8 Bore 1 244109 23 16 Bore 1 243276 244111 245090 2 Bore 1 244113 245092 27 16 Bore 1 244115 245094 2 Bore 1 245099 211 16 Bore 1 245110 215 16 Bore ...

Страница 7: ...se the adjustment of the bearings on each shaft assembly is affected REMOVING TAPER BUSHED REDUCER FROM SHAFT WARNING To ensure that drive is not unexpectedly started turn off and lock out or tag power source before proceeding Failure to observe these precautions could result in bodily injury WARNING External loads may cause machine movement Block machine before removing any drive train components...

Страница 8: ...just the input shaft bearings except the axial end play should be 002 to 004 Table 7 Bolt Tightening Torque Values Reducer Size Housing Bolts in lbs Seal Carrier Bolts in lbs HXT305A 600 204 HXT405A 600 360 HXT505A 900 360 8 Apply sealant to the input shaft cover gasket and install input shaft cover in right hand housing half Install input and output seals Extreme care should be used when installi...

Страница 9: ...9 Viscosity Classification Equivalents ...

Отзывы: