Mode Selection

The Mode selection  of the SR 400 D allows you to choose between a 1-In and 2-Out or a 2-In and 2-Out configur-
ation. To select either of the two modes, press the <Mode> button and use the <Data Wheel> to change the config-
uration mode. Once selected, press the <Store> button. 

To exit the Mode function, press the <Mode> button again.

Bypass Selection

By pressing the <Bypass> button on the front panel of the SR 400 D, this places the unit in Bypass mode. 
The unit will continue to pass signal.

SECTION 3- UTILITY MENU FUNCTIONS

The Utility menu within the  SR 400 D offers the User countless functions to help in 
programming and using the unit to its fullest potential.

The following pages give performance function notes for the all of the sub-menus of 
the SR 400 D.

Key Lock Out 

This unique function of the SR 400 D lets you lock-in your Delay settings and keep them that way.

To set the Key Lock, first press the <Utility> button and use the <Mode> button to scroll  to 
the right. Once you are at the Key lock function, turn the <Data Wheel> clockwise until the word: 

Locked

appears in the screen. Now a lock icon will appear in the display, indicating that the Delays are locked in place.

To unlock, press and hold the <Delay 2> button for approximately 5 seconds.

Temperature Unit Selection

The SR 400 D can display temperature in either Fahrenheit or Celsius Degrees. To select either one , press the 
<Utility> button and use the <Mode> button to scroll to right until Temp Units appears in the display. Now use the 
<Data Wheel> to select the measuring unit to be used.

LCD Contrast

To change the viewing display contrast of the SR 400 D, enter the Utility mode and use the <Mode> button to scroll 
to the LCD contrast. Now turn the <Data Wheel> to change the display contrast. Once the contrast has been set, 
press the <Utility> button to exit. 

Humidity

When Humidity in a room changes, it can effect Room delay. To change the percentage of humidity so the SR 400 D 
will calculate the correct delay, press the <Utility> button and use either the <Bypass> or <Mode> buttons  to 
scroll to the Humidity setting. Once there, the setting of Humidity can be changed. Range is 0 to 100% by using the 
<Data Wheel>.

Note: This utility function can only be used when the Delay Unit is being measured in Feet or Meters.

Signal Processing

6

Signal Processing

Signal Processing

SR 400D manual  6/8/99  10:54 AM  Page 6

Содержание SR400D

Страница 1: ...Harman Music Group Inc S Visit DOD on the World Wide Web at http www dod com SR 400D manual 6 8 99 10 54 AM Page 1...

Страница 2: ...ials and workmanship under normal use and service 3 DOD liability under this warranty is limited to repairing or replacing defective materials that show evidence of defect pro vided the product is ret...

Страница 3: ...ns 4 Channel 1 XLR Input 4 Barrier Strip Input Connection 4 Channel 2 XLR Input 5 Channel 1 XLR Output 5 Barrier Strip Output Connection 5 Channel 2 XLR Output 5 Power Adapter Input 5 SECTION 2 PROGRA...

Страница 4: ...t and output configurations with two independent programmable delays The SR 400 D also comes equipped with XLR and Barrier strip Inputs and Outputs as standard features Safety Precautions Do not open...

Страница 5: ...but more expensive are rack mount power supplies Some of these such as the DOD 828 have retractable light tubes and RF filtering AC line conditioners offer the best protection from improper line volta...

Страница 6: ...y unit 8 DELAY 2 This button is used to select Delay 2 for editing the delay unit 9 DATA WHEEL The Data Wheel is used to make edits to any of the selected functions 10 INPUT KNOB CHANNEL 1 Controls th...

Страница 7: ...in 00 0m Max 697 651m Delay Feet Min 00 0 f Max 2288 88f Note The Maximum Delay in Feet and Meters will vary depending on the Temperature and Humidity settings These Delay units can be changed in the...

Страница 8: ...he screen Now a lock icon will appear in the display indicating that the Delays are locked in place To unlock press and hold the Delay 2 button for approximately 5 seconds Temperature Unit Selection T...

Страница 9: ...temperature Once selected the SR 400 D will re calculate and the correct Delay is heard Note This utility function can only be used when the Delay Unit is being measured in Feet or Meters Factory Res...

Страница 10: ...Address 8760 S Sandy Parkway Sandy Utah 84070 USA declares that the product Product Name SR 400 D Product Options All with a Class II power adapter that conforms to the requirements of EN60065 EN6074...

Отзывы: