3) CHANNEL 2 XLR INPUT

- This is the Channel 2 INPUT XLR connector

4) CHANNEL 1 XLR OUTPUT

- This is the Channel 1 XLR Output connector.

5) BARRIER STRIP OUTPUT CONNECTION

- This is the Barrier strip connection for the Channel 1 and 2 outputs of 

the SR 400 D.

6) CHANNEL 2 XLR OUTPUT

- This is the Channel 2 Output XLR connector.

7) AC INPUT

- Connect the included DOD PS 750 power supply here.

SECTION 2 - PROGRAMMING THE SR 400 D

Selecting and Editing Delays

The SR 400 D is designed to be both easy to program and flexible. The structure of 
a SR 400 D is logical, and does not require a lot of time to master. 

1) After you power up, Select which delay you wish to edit. Press either <Delay 1> 
or <Delay 2> buttons.

2) Now use the <Data Wheel> to change the Delay times. The Delays can be set to 
be read as the following with the minimum and maximum values accordingly:

Delay Milliseconds -

Min.= 00.0ms

Max.= 2000.00ms

Delay Meters - 

Min.= 00.0m

Max.= 697.651m

Delay Feet - 

Min.= 00.0 f

Max.= 2288.88f

Note: The Maximum Delay in Feet and Meters will vary depending on the Temperature and Humidity settings.

These Delay units can be changed in the utility menu.
Once the satisfactory delay unit has been entered, simply press the <Store> button 
to save changes.

Temperature

Since temperature plays such a big part of in acoustics of room delay, the SR 400 D 
lets you change enter in the temperature of the room, then the SR 400D will do the 
calculating to change the delay time. This change will cause the Audio signal to arrive at its Point of 
sound destination at the correct time. 

Humidity

Humidity also plays a factor in the fluctuation of Room Delay times. The SR 400 D allows you to change the 
Humidity percentage (this is performed in the utilities menu), so the sound reaches its Audio destination at the cor-
rect time.

Storing Delay Presets

Once all of the elements are in place and Delay settings are correct, simply press the store button and all changes 
will be saved.

Signal Processing

5

Signal Processing

SR 400D manual  6/8/99  10:54 AM  Page 5

Содержание SR400D

Страница 1: ...Harman Music Group Inc S Visit DOD on the World Wide Web at http www dod com SR 400D manual 6 8 99 10 54 AM Page 1...

Страница 2: ...ials and workmanship under normal use and service 3 DOD liability under this warranty is limited to repairing or replacing defective materials that show evidence of defect pro vided the product is ret...

Страница 3: ...ns 4 Channel 1 XLR Input 4 Barrier Strip Input Connection 4 Channel 2 XLR Input 5 Channel 1 XLR Output 5 Barrier Strip Output Connection 5 Channel 2 XLR Output 5 Power Adapter Input 5 SECTION 2 PROGRA...

Страница 4: ...t and output configurations with two independent programmable delays The SR 400 D also comes equipped with XLR and Barrier strip Inputs and Outputs as standard features Safety Precautions Do not open...

Страница 5: ...but more expensive are rack mount power supplies Some of these such as the DOD 828 have retractable light tubes and RF filtering AC line conditioners offer the best protection from improper line volta...

Страница 6: ...y unit 8 DELAY 2 This button is used to select Delay 2 for editing the delay unit 9 DATA WHEEL The Data Wheel is used to make edits to any of the selected functions 10 INPUT KNOB CHANNEL 1 Controls th...

Страница 7: ...in 00 0m Max 697 651m Delay Feet Min 00 0 f Max 2288 88f Note The Maximum Delay in Feet and Meters will vary depending on the Temperature and Humidity settings These Delay units can be changed in the...

Страница 8: ...he screen Now a lock icon will appear in the display indicating that the Delays are locked in place To unlock press and hold the Delay 2 button for approximately 5 seconds Temperature Unit Selection T...

Страница 9: ...temperature Once selected the SR 400 D will re calculate and the correct Delay is heard Note This utility function can only be used when the Delay Unit is being measured in Feet or Meters Factory Res...

Страница 10: ...Address 8760 S Sandy Parkway Sandy Utah 84070 USA declares that the product Product Name SR 400 D Product Options All with a Class II power adapter that conforms to the requirements of EN60065 EN6074...

Отзывы: