ENGLISH
DIMENSION
: see page 5.
INSTALLATION
: see pages 6 to 7 - diagrams 1 to 16.
MAINTENANCE
: see instructions below and diagrams at page 7.
NOTES
* only two screws can be used to fix the valve.
* the flexible hoses can be cut according to the installation.
THIS PACKAGE CONTAINS:
SPARE PARTS
:Available at Docol Authorized Distributor in your country/ Export Departament + 55 47 3451-1114 or
INSTRUCTION STICKER
: stick it at the wall close the spout.
CARE AND CLEANING:
only use soft cloth, water and soft soap once a week. Occasionally can be applyed automobiles wax. Do not use
abrasive products.
WARRANTY
: Call Docol Authorized Distributor in your country/ Export Depar 55 47 3451-1114 or [email protected]
For a better perfomance of the hydraulic system, we recommend following a project made by a specialized professional as well as all
relevant standards and the installation standard.
1 Pedalmatic valve, 2 flexible hoses, 1 angle stop, 1 instruction manual, 1 instruction sticker, 7 screws, 7
universal fixings and 3 clamps.
PROBLEM
PROBABLE CAUSE
Water supply interrupted
Check/open supply pipe
Angle stop valve not opened
Angle stop filter clogged
Clean or replace (diagram 17 - 18)
Aerator clogged
Clean or replace (diagram 19)
Piston damaged (diagram 23-part A)
Replace (diagrams 20 - 23)
Spindle damaged (diagram 23-part B)
Replace (diagrams 20 - 23)
Seat damaged (diagram 23-part C)
Replace (diagrams 20 - 23)
Water flow time too long Piston damaged/clogged (diagram 23-part A)
Replace (diagrams 20 - 23)
Angle stop not installed
Install and adjust (diagram 7)
Angle stop totally opened
Adjust the flow rate (diagrams 16)
Retainer damaged (diagram 23-part D)
Replace (diagrams 20 - 23)
Spindle damaged (diagram 23-part B)
Replace (diagrams 20 - 23)
SOLUTION
Flow volume too high
Leak under the lever
Water does not flow or
flow volume too low
Water flow s
continuously (leak)
Open (diagrams 16)
4