17
Maintenance
Water flows intermittently
Infiltration of water between escutcheon and bench
Sensor boot faiture
Sensor damaged
Checking the sealing of the escutcheon
Disconnect and reconnect power cable
Available at Docol Authorized Distributor in your country
SYMPTOMS
POSSIBLE REASONS
SOLUTIONS
Water does not flow:
Solenoid valve produces an audible “click”,
Led lights up the escutcheon
Water supply failure
Open water supply stop valve
Open the Inlet flow control
Inlet flow control
Disassemble and clean the core of Inlet Flow control filter.
Unavailability of electricity to the sensor
Verify overload protect
Power cord is not connected in the electrical outlet
Connect power cord to power inlet
Connect the cableas again
Sensor not connected to the solenoid valve
Reconnect the sensor cable to the valve
Sensor boot faiture
Low flow
Inlet flow control not enough open
Rotate the cartridge clockwise RRC
Disconnect and reconnect power cable
Bad connection between sensor and power supply
Water does not flow:
Solenoid valve does not produces audible
“click”
Air inside pipe system
Open the network elsewhere in the network and bleed (let out until
water stops coming out with air and water)
Faulty sensor
Available at Docol Authorized Distributor in your country
Dirt in the pipe
Water supply stop is partially closed
Remove, clean and reinstall the aerator
Water supply stop is partially closed
Fully open the general log
Non-aerated water jet
Product installed in a pressure below
1,0 kgf/cm² / 1,0 bar / 10 m.c.a
Remove the flow restrictor ( See page 9)
Disassemble and clean the core of Inlet flow control filter