3. COMMISSIONING

If the springs are weak or broken, or the weight of the door is not balanced properly, operating the drive can lead 

to uncontrolled movements of the door.

During commissioning, you must remain inside the garage. This means that you can open the door using the manual 

unlocking mechanism in the event of a fault.

3.1 Menu controls

ALL FUNCTIONS, OPERATING SEQUENCES AND ADJUSTMENT & SETTING OPTIONS HAVE BEEN PRESENTED AT A GLANCE 

AND AS BRIEF INSTRUCTIONS ON PAGE 8 OF THIS MANUAL!

First, loosen the screw on the light cover. Remove the light cover from the housing (FIG. 28).

OPERATING THE MENU CONTROLS

1) ENABLING (ACTIVATING) THE MENU:
Press the MENU button and hold for about 3 sec.: The green LED begins to flash, and in the multi-segment display (hereinafter 

referred to as "Display") the first submenu "P" (= Program, learn drive) appears.

2) NAVIGATION WITHIN THE MENU:
You can enter the menu option displayed respectively with a single character by pressing briefly on the ENTER button ("Con-

firm selection") or switch to the next menu option by pressing briefly on the SCROLL button ("Page"); the sequence is fixed 

and paging always takes place in one direction (see sequence in the description of the menu options)!

3) NAVIGATION IN THE MENU OPTION (! Please take note of the exceptions in "P" and "b" !)
If you have selected the desired menu option by pressing briefly on the ENTER button, the display then switches to a nume-

rical value between "1" and "9", which represents the status of the function or setting that has been configured: by pressing 

briefly the SCROLL button, you can page through these setting options, which are always in increasing order; if the respec-

tive maximum value is reached, pressing the SCROLL button once again restarts paging with "1".
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Page through the options with the SCROLL button until you reach the desired selection and confirm it by briefly pressing the 

ENTER button: The display changes once again to that of the menu option, and the desired value set by you is accepted.
4) SAVE AND QUIT MENU:
The last menu option is "E" ("End"), which does not provide any setting options and merely displays the end of the menu: 

Briefly press the ENTER button in order to quit the menu and to save the settings selected (green LED goes off). If you wish to 

return to the menu, press the SCROLL button instead: in this case, the menu begins once again with the first menu option "P".
 

3.2 Programming path and force ("P")

The attachment (FIG. 7, a) must be latched and locked in the carriage (FIG. 13). The factory setting for the force (stage 5) 

may not be changed before performing the learning procedure! 

 

During the learning movement, evaluation of the light barrier and hindrance detection system or the power-opera-

ted shutdown does not take place!

Nobody may remain in the hazard zone of the garage door during commissioning and when adjustments are being 

made!

 

• Enter (activate) the menu and go to the menu option "P" with ENTER: "1." appears in the display. Activate the drive in the 

open direction by pressing the START button (display switches to "1.") and stop it just before it reaches the end position 

"Door open"; move it the last few centimetres by pressing the button briefly and repeatedly in order to ensure the correct 

end position.  

• End the procedure by pressing briefly on the SCROLL button, enable (activate) the stand-by for closing, and "2" appears 

in the display.

• Re-activate the drive by pressing the START button (display switches to "2.") and stop it just before it reaches the end po-

sition "Door closed"; move it the last few centimetres by pressing the button briefly and repeatedly in order to ensure the 

correct end position.

• End the procedure by pressing briefly on the SCROLL button, enable (activate) the readiness for the subsequent learning 

movement for force measurement: "3" appears in the display.

• Now press the START button briefly: the display changes to "3." and the drive performs a complete and automatic cycle 

from an open condition to close, in order to obtain the exact values of the force. The display switches to "4." at the end of 

the door opening movement, as well as at the beginning of the close operation. If the door is closed again, the procedure 

ends, and the display indicates this status by returning to the menu: "P" appears in the display: 

• Quit the menu by pressing the SCROLL button and paging to the end of the menu "E" and quit the menu with ENTER (alter-

natively: configure other desired settings in the subsequent menu options). 

DOCO

MATIC

 

 

 

 

 

 

13/23 

 

 

 

 

 

04-10

Содержание DOCOMATIC 1200

Страница 1: ...DOCOMATIC 1200 Installation Manual With tips on operation and maintenance Garage door drives Art Nr 501003 GB DOCOMATIC 1 23 04 10 ...

Страница 2: ...1 2 3 4 5 6 8 7 Ø3 Ø10 Ø5 6 10 13 17 a b e c d 1 2 3 4 Motor a DOCOMATIC 2 23 04 10 ...

Страница 3: ...10 13 14 15 16 11 12 9 a b d c b a a b c 0 5 cm 0 5 cm DOCOMATIC 3 23 04 10 ...

Страница 4: ...18 21 22 23 24 19 17 20 a Ø10 c Ø10 b 90 5 7cm max 30 DOCOMATIC 4 23 04 10 ...

Страница 5: ...26 29 30 31 32 27 25 28 2x 4x a b Ø5 b 1 2 a Ø3 a b DOCOMATIC 5 23 04 10 ...

Страница 6: ...5 01 04 01 03 02 02 01 01 01 02 03 00 03 01 02 01 01 07 01 06 06 00 BY 1270 BY 1225 10 00 2x 05 01 05 02 05 03 04 02 04 01 04 03 06 01 06 04 06 02 07 02 07 03 07 04 07 00 07 01 05 00 od e r 04 00 06 03 06 01 01 08 10 01 0 5 2 1 Y B 08 01 08 02 08 03 08 00 08 04 09 XX 08 05 08 XX 09 00 09 01 09 02 02 00 DOCOMATIC 6 23 04 10 ...

Страница 7: ... delivery Only non latching contacts e g push buttons may be connected to START 1 2 and never self holding or latching contacts e g switch Self holding contacts generate a continuous signal and therefore they block all other func tions Control board B 300 01 OKP Wireless receiver on the plug in socket Molex B 300 01 OKP Motor 24 V DC Transformer Secondary Earth base plate Start command Light barri...

Страница 8: ... the value set is always displayed the characters displayed in bold represent the pre programmed factory setting You can page through the individual values respectively using SCROLL After reaching the maximum value pressing the SCROLL button once again will display the mini mum value You can quit the respective menu with ENTER which always saves the current value displayed After completing the set...

Страница 9: ...ons use of safety equipment and devices EN 13241 1 Garage door product standard EN 12635 Installation and operation requirements EN 12453 Safety issues when using power opera ted doors and roller shutters 2006 42 EC Machinery Directive Electrical installations 230V at site may only be carried out by skilled electrical technicians The safety rules and regulations applicable for ac cident prevention...

Страница 10: ...e Before installing the drive the garage door must be in proper mechanical condition It must be possible to operate the door by hand without applying any large amount of force and it must remain fixed in any position when it is stopped The garage door must be checked by qualified specialists and if the above condition is not fulfilled it must be repaired before installing the drive The lintel and ...

Страница 11: ...f the mushroom head bolt is correctly seated in the deflection roller assembly holder FIG 12 Tighten the drive medium The chain or the toothed belt must then be pre tensioned to such an extent that the chain or the toothed belt does not drop down any longer FIG 13 Test the carriage Finally check whether the carriage can be moved easily in the rail To do this operate the emergency unlocking lever o...

Страница 12: ... cover in place After all of the work has been completed please ensure that the light cover is put back in place and fastened with the screw provided 2 4 Affix warning labels The warning label which draws attention to the risk of jamming and serves as a reminder for regular checking of the hindrance detection system must be permanently affixed at a clearly visible location or in the vicinity of th...

Страница 13: ...enu Briefly press the ENTER button in order to quit the menu and to save the settings selected green LED goes off If you wish to return to the menu press the SCROLL button instead in this case the menu begins once again with the first menu option P 3 2 Programming path and force P The attachment FIG 7 a must be latched and locked in the carriage FIG 13 The factory setting for the force stage 5 may...

Страница 14: ...unters a mass of 20 Kg at the centre of the lower edge of the door safety shutdown to protect against lifting human beings other objects 3 5 Add on functions in the menu The add on functions listed in the following passage are used to adjust and adapt the garage door drive to every specific installation and therefore they should only be used in case of adaptation to the application Further infor m...

Страница 15: ...briefly on ENTER POINT 1 REVERSING BEHAVIOUR This specifies whether the drive performs a partial or complete reversal when a hindrance is detected POINT 2 SOFT MOVEMENT FUNCTION This enables the selection of a short approx 7 cm or long approx 15 cm soft movement function at the beginning and end of the door movement the longer phase leads to more gentle braking and closure POINT 3 AUTOMATIC DOOR C...

Страница 16: ...er of the machine or his authorised representative must effect the EC Declaration of Conformity in accordance with MRL 2006 42 EC Appendix II 1 A and the CE mark in accordance with MRL 2006 42 EC Appendix III 3 10 Handing over and user training Hand over the machine including the documentation see EN 12635 to the owner of the system Please ensure that the operator and user are briefed and trained ...

Страница 17: ...r of light barriers is used they must be installed opposite one another and connected in series The positive voltage supply 24 V of the transmitter light barrier TX and receiver light barrier RX is fed on terminal 5 The negative power supply 0 V of the transmitter light barrier is fed at terminal 6 wired earth and the negative voltage supply of the receiver light barrier is connected to terminal 8...

Страница 18: ... rating of max 1A in order to rule out any damage to the controller The maximum contact load bearing capacity is 1A on 230 V AC or 30 V DC Use suitable cable for the connection of the door status indication or warning lamp in keeping with the voltage load used We recommend that the warning lamp be installed at a point that is exposed as far as possible and above all can be seen easily from all pos...

Страница 19: ...NT FOR SAFEGUARDING HUMAN LIVES TO COMPLY WITH ALL INSTRUCTIONS THESE INSTRUCTIONS MUST BE KEPT IN SAFE CUSTODY When operating the emergency unlocking mechanism there can be uncontrolled movements of the garage door if springs are weak or broken or if the door is not balanced by weight The emergency unlocking mechanism may only be operated when the mains plug has been removed 5 1 Instructions for ...

Страница 20: ...R TO LIFE Faults in the 230 V part of the system may only be attended to by skilled electrical technicians Service and repair work may only be carried out by qualified and skilled technicians Please do not operate the system if service or repair work is required Every time that the 230 V AC mains power supply is switched on the first thing the control electronics will do is to perform a self test ...

Страница 21: ...installation Correct the force setting Door opens slightly and switches off after with a new installation Force setting too low Correct the force setting Door is too heavy Use a drive with higher power rating Push rod angle too large Correct the installation Door is very stiff Have maintenance carried out on the door Door closes slightly and switches off reverses Change in the door mechanics Have ...

Страница 22: ... weeks Any faults must be attended to imme diately by a qualified and skilled technician FIG 29 The following parts of the drive are subject to wear and tear and must be replaced after 80 000 operating cycles or 10 years at the latest Toothed belt 04 00 04 03 chain 05 00 05 02 deflection roller assembly 07 00 07 04 drive as sembly 6 00 06 04 and geared motor 01 02 Chains should be lubricated sligh...

Страница 23: ...m range Flap door contact Safety switch strip 8 2 Kohm Warning lamp 24 V 15 W Flash lamp 230 V 15 W Signal module Green signal Red signal Rail extension 1 00 m Rail extension 2 00 m Rail extension 3 00 m Push rod extender Various lengths on request Supplementary locking set for the sectional door Supplementary locking set for the hinged door Sectional door fitting Swing door fitting Curved door ar...