background image

4.0 CONNECTING ACCESSORIES

Remove the mains plug before laying any wiring or connections to the controller in order to prevent damage to the 

controller! 

 

Always lay the control and signal lines in such a way that they are separate and isolated from power cables in  

 

order to prevent interferences.

4.1Buttons

 

Only non-latching NO (normally open) contacts (not self-holding or latching contacts of a switch or similar!) may  

 

be used! Only potential-free contacts may be connected - never connect any external power supply!

Connect the button contacts to terminals 1 and 2 of the control board (FIG. 38). If more than one element is used for this 

connections, the contacts must be connected in parallel. Use cables having a core diameter of at least 0.25 mm² for maxi-

mum length of 20 m. Operating elements that are permanently installed must be within sighting range of the garage door. 

The distance between moving parts and the height above the ground must be at least 1.8 metres. They must be mounted 

beyond the reach of children under all circumstances! 

4.2 Light barrier

The light barrier must be enabled (activated) in the menu "b" option "4" (see 3.5 or the brief instructions on page 8)! 

The use of a light barrier generally enhances the safety of the garage door system and can become urgently necessary 

under certain circumstances (e.g. contact with public places or minimum level of protection in accordance with EN 12453).

If the light beam gets interrupted during the door closing movement, the garage door stops immediately and reverses 

about 10 cm in the direction of door opening (or performs complete reversal: see 3.5 / b: binary add-on functions / POINT 

1). The light barrier is inactive during the door opening movement.

Use cables with a core diameter of at least 0.25 mm² for a maximum length of 20 m. We recommend that the light barrier 

be located at a height of 40 cm above the ground and as close as possible to the door (max. 50 mm away). If more than 

one pair of light barriers is used, they must be installed opposite one another and connected in series.

The positive voltage supply (+24 V) of the transmitter light barrier TX and receiver light barrier RX is fed on terminal 5. The 

negative power supply (0 V) of the transmitter light barrier is fed at terminal 6 (wired earth), and the negative voltage supply 

of the receiver light barrier is connected to terminal 8 (earth). Connect the signal output of the receiver light barrier (RX) to 

terminal 7 (S) and to earth (terminal 8). After completing the installation, test the operation of the light barrier by interrupting 

the light beam using some object (e.g. a broom).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4.3 Safety switch strip 

 

 

 

 

 

 

 

 

 

 

 

 

 

The safety switch strip must be enabled (activated) in the menu "b" option "5" (see 3.5 or the brief instructions on  

 

page 8)! 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The controller allows direct evaluation of the resistive safety switch strips with 8, 20 and 22.00 Kohm. If a light barrier is not used 

simultaneously, the safety switch strip is connected directly to the terminals 7 (signal) and 8 (earth). 

If light barriers and safety switch strips are used simultaneously, the latter must be wired in series with the receiver signal of 

the light barrier after the terminal 7 (signal). In this case, both the devices must be enabled in 

menu "b" ("4" as well as "5"), i.e. defined as active. After completing the installation, test the operation of the safety switch 

strip by manually applying counter-pressure to it.

4.4 Antenna (plug-in receiver)

Please  use  only  an  antenna  with  a  suitable  (=matching)  frequency 

and screened (or shielded) coaxial cable. Do not modify the antenna 

under any circumstances.

• Remove the dipole (wire) antenna fixed to the antenna connection ANT of 

the wireless receiver.

• Connect the inner conductor (1) of the supplementary antenna to the an-

tenna connection ANT and connect the screen (or shield) (2) to the ┴ termi-

nal.

• Lay the antenna outside the garage and place it at a point that is exposed 

and at as high a location as possible with a line of vision to the operating 

location.

Do not extend the coaxial cable provided on the antenna and do not use 

more than one antenna simultaneously on the device.

1

2

DOCO

MATIC

 

 

 

 

 

 

17/23 

 

 

 

 

 

04-10

Содержание DOCOMATIC 1200

Страница 1: ...DOCOMATIC 1200 Installation Manual With tips on operation and maintenance Garage door drives Art Nr 501003 GB DOCOMATIC 1 23 04 10 ...

Страница 2: ...1 2 3 4 5 6 8 7 Ø3 Ø10 Ø5 6 10 13 17 a b e c d 1 2 3 4 Motor a DOCOMATIC 2 23 04 10 ...

Страница 3: ...10 13 14 15 16 11 12 9 a b d c b a a b c 0 5 cm 0 5 cm DOCOMATIC 3 23 04 10 ...

Страница 4: ...18 21 22 23 24 19 17 20 a Ø10 c Ø10 b 90 5 7cm max 30 DOCOMATIC 4 23 04 10 ...

Страница 5: ...26 29 30 31 32 27 25 28 2x 4x a b Ø5 b 1 2 a Ø3 a b DOCOMATIC 5 23 04 10 ...

Страница 6: ...5 01 04 01 03 02 02 01 01 01 02 03 00 03 01 02 01 01 07 01 06 06 00 BY 1270 BY 1225 10 00 2x 05 01 05 02 05 03 04 02 04 01 04 03 06 01 06 04 06 02 07 02 07 03 07 04 07 00 07 01 05 00 od e r 04 00 06 03 06 01 01 08 10 01 0 5 2 1 Y B 08 01 08 02 08 03 08 00 08 04 09 XX 08 05 08 XX 09 00 09 01 09 02 02 00 DOCOMATIC 6 23 04 10 ...

Страница 7: ... delivery Only non latching contacts e g push buttons may be connected to START 1 2 and never self holding or latching contacts e g switch Self holding contacts generate a continuous signal and therefore they block all other func tions Control board B 300 01 OKP Wireless receiver on the plug in socket Molex B 300 01 OKP Motor 24 V DC Transformer Secondary Earth base plate Start command Light barri...

Страница 8: ... the value set is always displayed the characters displayed in bold represent the pre programmed factory setting You can page through the individual values respectively using SCROLL After reaching the maximum value pressing the SCROLL button once again will display the mini mum value You can quit the respective menu with ENTER which always saves the current value displayed After completing the set...

Страница 9: ...ons use of safety equipment and devices EN 13241 1 Garage door product standard EN 12635 Installation and operation requirements EN 12453 Safety issues when using power opera ted doors and roller shutters 2006 42 EC Machinery Directive Electrical installations 230V at site may only be carried out by skilled electrical technicians The safety rules and regulations applicable for ac cident prevention...

Страница 10: ...e Before installing the drive the garage door must be in proper mechanical condition It must be possible to operate the door by hand without applying any large amount of force and it must remain fixed in any position when it is stopped The garage door must be checked by qualified specialists and if the above condition is not fulfilled it must be repaired before installing the drive The lintel and ...

Страница 11: ...f the mushroom head bolt is correctly seated in the deflection roller assembly holder FIG 12 Tighten the drive medium The chain or the toothed belt must then be pre tensioned to such an extent that the chain or the toothed belt does not drop down any longer FIG 13 Test the carriage Finally check whether the carriage can be moved easily in the rail To do this operate the emergency unlocking lever o...

Страница 12: ... cover in place After all of the work has been completed please ensure that the light cover is put back in place and fastened with the screw provided 2 4 Affix warning labels The warning label which draws attention to the risk of jamming and serves as a reminder for regular checking of the hindrance detection system must be permanently affixed at a clearly visible location or in the vicinity of th...

Страница 13: ...enu Briefly press the ENTER button in order to quit the menu and to save the settings selected green LED goes off If you wish to return to the menu press the SCROLL button instead in this case the menu begins once again with the first menu option P 3 2 Programming path and force P The attachment FIG 7 a must be latched and locked in the carriage FIG 13 The factory setting for the force stage 5 may...

Страница 14: ...unters a mass of 20 Kg at the centre of the lower edge of the door safety shutdown to protect against lifting human beings other objects 3 5 Add on functions in the menu The add on functions listed in the following passage are used to adjust and adapt the garage door drive to every specific installation and therefore they should only be used in case of adaptation to the application Further infor m...

Страница 15: ...briefly on ENTER POINT 1 REVERSING BEHAVIOUR This specifies whether the drive performs a partial or complete reversal when a hindrance is detected POINT 2 SOFT MOVEMENT FUNCTION This enables the selection of a short approx 7 cm or long approx 15 cm soft movement function at the beginning and end of the door movement the longer phase leads to more gentle braking and closure POINT 3 AUTOMATIC DOOR C...

Страница 16: ...er of the machine or his authorised representative must effect the EC Declaration of Conformity in accordance with MRL 2006 42 EC Appendix II 1 A and the CE mark in accordance with MRL 2006 42 EC Appendix III 3 10 Handing over and user training Hand over the machine including the documentation see EN 12635 to the owner of the system Please ensure that the operator and user are briefed and trained ...

Страница 17: ...r of light barriers is used they must be installed opposite one another and connected in series The positive voltage supply 24 V of the transmitter light barrier TX and receiver light barrier RX is fed on terminal 5 The negative power supply 0 V of the transmitter light barrier is fed at terminal 6 wired earth and the negative voltage supply of the receiver light barrier is connected to terminal 8...

Страница 18: ... rating of max 1A in order to rule out any damage to the controller The maximum contact load bearing capacity is 1A on 230 V AC or 30 V DC Use suitable cable for the connection of the door status indication or warning lamp in keeping with the voltage load used We recommend that the warning lamp be installed at a point that is exposed as far as possible and above all can be seen easily from all pos...

Страница 19: ...NT FOR SAFEGUARDING HUMAN LIVES TO COMPLY WITH ALL INSTRUCTIONS THESE INSTRUCTIONS MUST BE KEPT IN SAFE CUSTODY When operating the emergency unlocking mechanism there can be uncontrolled movements of the garage door if springs are weak or broken or if the door is not balanced by weight The emergency unlocking mechanism may only be operated when the mains plug has been removed 5 1 Instructions for ...

Страница 20: ...R TO LIFE Faults in the 230 V part of the system may only be attended to by skilled electrical technicians Service and repair work may only be carried out by qualified and skilled technicians Please do not operate the system if service or repair work is required Every time that the 230 V AC mains power supply is switched on the first thing the control electronics will do is to perform a self test ...

Страница 21: ...installation Correct the force setting Door opens slightly and switches off after with a new installation Force setting too low Correct the force setting Door is too heavy Use a drive with higher power rating Push rod angle too large Correct the installation Door is very stiff Have maintenance carried out on the door Door closes slightly and switches off reverses Change in the door mechanics Have ...

Страница 22: ... weeks Any faults must be attended to imme diately by a qualified and skilled technician FIG 29 The following parts of the drive are subject to wear and tear and must be replaced after 80 000 operating cycles or 10 years at the latest Toothed belt 04 00 04 03 chain 05 00 05 02 deflection roller assembly 07 00 07 04 drive as sembly 6 00 06 04 and geared motor 01 02 Chains should be lubricated sligh...

Страница 23: ...m range Flap door contact Safety switch strip 8 2 Kohm Warning lamp 24 V 15 W Flash lamp 230 V 15 W Signal module Green signal Red signal Rail extension 1 00 m Rail extension 2 00 m Rail extension 3 00 m Push rod extender Various lengths on request Supplementary locking set for the sectional door Supplementary locking set for the hinged door Sectional door fitting Swing door fitting Curved door ar...

Отзывы: