Out of the Water 

 

Don’t panic;  

 

Proceed to Shore 

 

Kill Power to the dock via the circuit break on the shore 

 

Call 911 and your local electrician 

WARNING! 

Alarms have various limitations.  See “Limitations of Stray Electricity Detectors” for details. 

Calling a Qualified Electrician to Find and Repair the Problem 

If the Dock Lifeguard units detects stray electricity in the water.  Contact a local electrician that is 
familiar with local electrical codes on boat docks to diagnose and solve the problem. 

If You Suspect a Problem 

Dock Lifeguard may not operate properly because of faulty power supply or installation in an improper 
location.  Clean the Dock Lifeguard as described in “Regular Maintenance”, then test the detector again.  
If it fails to test properly when you use the test button, or if the problem persists, replace the Dock 
Lifeguard unit immediately. 

 

If you experience frequent non-emergency alarms: 

o

 

Check and Measure for electricity in the water 

o

 

Very proper for proper safety ground bonding of your dock. 

Technical Information 

Lethal Voltage is 2 volts AC per foot.   The Dock Lifeguard units are setup to trigger at approximately 
1500 millivolts.   To see exact settings of your system, you need to reference the sensitivity jumper 
settings on the mother board and trigger level of the alarm, as these items are configurable. 

The following link a reference to the USCG In-Water Shock Hazard Mitigation Strategies. 

http://www.boatus.com/seaworthy/assets/pdf/in-water-shock-hazard-mitigation-strategies.pdf

 

Product Specifications 

Sensitivity meter is in 125 millivolt levels.    Sensitivity can be increased by setting jumpers on the 
mother board.   Refer to YouTube video on the DockLifeguard.com website on how to set the jumpers. 

How the Unit Determines When to Alarm 

The default factory  setting of the Dock Lifeguard will trigger when stray electricity is detected in the 
water above the unit threshold of approximately 1500 millivolts.  This trigger sensitivity will increase 
with increased levels sensitivity via the sensitivity jumpers and trigger point adjustments made on the 
motherboard. 

 

Alarm Trigger Level

: The trigger level of the alarm can be adjusted to help 

filter out higher levels of ambient voltage in the water or to alarm at a 

Содержание DOCK LIFEGUARD

Страница 1: ...Users Guide Basic Version 1 1...

Страница 2: ...probe This unit can ONLY give detection if it is installed maintained and located where stray electricity can reach it and where all residents can hear it as described in this manual This unit cannot...

Страница 3: ...horn at close range may harm your hearing Recommended Locations for Dock Lifeguard Install your Dock Lifeguard with an unobstructed view to allow viewing of the warning strobe when electricity is dete...

Страница 4: ...unded dock and to the ground of the electrical system of the dock Note You must have a proper bond of the dock lifeguard green wire to the dock safety ground for correct operation Pier Docks with Wood...

Страница 5: ...t to a metal underwater structure such as underwater bracing sea anchor cables or steel underwater dampening structures Non Detection Zones Underwater structures such as sea anchors with metal extrudi...

Страница 6: ...continued usefulness For instance the probe may gather algae after a long time in the water Wiping it clean annually will ensure that the range of the probe stays as consistent as possible In additio...

Страница 7: ...ash WARNING If the unit alarms and you are not testing the unit it is a warning of potentially dangerous situation that requires immediate attention NEVER ignore any alarm Ignoring the alarm may resul...

Страница 8: ...l Information Lethal Voltage is 2 volts AC per foot The Dock Lifeguard units are setup to trigger at approximately 1500 millivolts To see exact settings of your system you need to reference the sensit...

Страница 9: ...rigger Level Factory setting is set to trigger alarm when 4 LEDs are lit Alarm trigger point can be raised by turning the potentiometer counter clockwise and lowered by turning the potentiometer clock...

Страница 10: ...allow for adjusting the sensitivity level of the Dock Lifeguard unit The more sensitive the setting the further out the Dock Lifeguard will detect stray voltage X0 Nothing Jumped each LED 0 5 Volts X...

Страница 11: ...s common on Smith Lake AL Sensitivity will need to be decreased and the Alarm level raised in order to filter out the ambient voltage With decreased sensitivity comes decreased range of detection It i...

Страница 12: ...tors are not foolproof Like any electronic device Dock Lifeguard is made of components that can wear out or fail at any time You must test the unit weekly to ensure your continued protection Dock Life...

Страница 13: ...ate insurance coverage is your responsibility Consult your insurance agent For Warranty Service In many cases the quickest way to exchange your alarm is to return it to the original place of purchase...

Страница 14: ...and 1 volt Depending on your sensitivity settings of your unit then number of LEDs shown on the front of the display will reflect this ambient voltage i e You sensitivity jumper setting is set to 0 25...

Отзывы: