LPG CYLINDER 

  LPG cylinder used must be in accordance with the National Rules in force. 

  LPG cylinder should have collar to protect cylinder valve and never filled over 80% its capacity. 

  Refer to your gas supplier for instructions how to use and handle LPG cylinder. 

  Never use a LPG cylinder with a damaged body, valve, collar or foot ring. 

  Change LPG cylinders in an amply ventilated area, away from any ignition source (candle, cigarettes and so 

on). 

  If appliance is stored indoors, detach and leave LPG cylinder outdoors in a ventilated and protected area. 

  LPG cylinder must always be used in an upright position. 

  Do not store a spare or disconnected LPG cylinder near this appliance. 

 

 

IMPORTANT SAFETY RULES 

This appliance is not fitted with “Atmosphere sensing device”. 

To be used outdoors use only and in good weather condition (no rain, or windy condition). 

The use of this appliance in enclosed areas can be dangerous and is PROHIBITED. 

Children and adults should be aware of the high operating temperatures of areas above the post when operating 

this appliance. Children should be carefully supervised when in the vicinity of the appliance.   

NEVER

 hang anything, including clothes or any other flammable items, on this appliance.   

DO NOT

 operates this appliance unless it is fully assembled with all its parts. 

Minimum  clearance  is  1  m  from  combustible  materials  and  or  any  wall  side  (left,  right  or  back);  any  ceiling  is 

forbidden. 

Appliance is not fitted with any guard; it is recommended to use one for the protection of young children, the elderly 

or infirm. The approach to the appliance is limited such that accessibility to the flame is minimized. 

Do not stay too closed to the appliance while in operation. 

 
 

MAINTENANCE AND CLEANING 

To enjoy years of outstanding performance from your appliance, regular services of the appliance is mandatory as 

followings: 

  The  appliance  should  be  inspected  before  at  least  one  time  a  year  by  a  Qualified  Service  only.  More  frequent 

cleaning may be required according to the use of the appliance. 

  Keep exterior surfaces clean, 

free and clear from combustible materials.

 

  Use warm soapy water for cleaning. Never use flammable or corrosive cleaning agents. 

  While washing your unit makes sure to keep the area around the burner assembly dry at all times. If the gas 

control is exposed to water in any way, 

DO NOT 

tries to use it. It must be replaced. 

  Burner and LPG compartment circulating air passageways of the appliance must be kept clean. 

  Airflow must be unobstructed. Keep controls, burner and circulation air passageways clean. Signs of possible 

blockage include: 

  Gas odor with extreme yellow tipping of flame / Appliance glow is excessively uneven / Appliance makes popping 

noises. 

  Spiders and insects can nest in burner or orifices. This dangerous condition can damage the appliance and render 

Содержание 35441E

Страница 1: ...se Warning Accessible parts may be very hot keep young children away This appliance must be installed in accordance with the rules in force and used only in a sufficiently ventilated space Consult ins...

Страница 2: ...3 mm x 1 pcs Destination countries AT DE SK CH LU Gas regulator Certified regulator according to EN 16129 flow rate max 1 5kg h Gas hose Certified gas hose according to applicable EN standard max1 5m...

Страница 3: ...y your self Never use this appliance until all connections have been leakage tested Never put it into operation if any leakage is detected check leakage all the time by soapy foam never using a flame...

Страница 4: ...ay away to avoid burns or clothing ignition If fire should go out turn gas supply in OFF position full disk and wait for 2 minutes before attempting to relight Children should be carefully supervised...

Страница 5: ...5 of 11 EXPANDED VIEW...

Страница 6: ...re supplied with this appliance and must be used according to National Rules in force You need to purchase one gas regulator and one gas cylinder The gas regulator has to be set according to specific...

Страница 7: ...aximum position big flame stop pushing ignition button star and keep the control knob pressed but not over 20 seconds to heat the thermocouple FSD then release it first ignition take generally more ti...

Страница 8: ...ing to EN 549 Class B2 or material used to guarantee tightness according to EN 751 1 Class I GAS REQUIREMENTS Use only the type of gas and the type of LPG cylinder specified by the manufacturer Applia...

Страница 9: ...inimum clearance is 1 m from combustible materials and or any wall side left right or back any ceiling is forbidden Appliance is not fitted with any guard it is recommended to use one for the protecti...

Страница 10: ...embling battery Please contact the Manufacturer or dealer for information regarding replacement hoses thermocouples igniters lava rocks etc Attention Never use unauthorized parts or component for this...

Страница 11: ...ressure Replace LPG cylinder with a new one Burner flame is low Note Do not operate appliance below 5 C Outdoor temperature is greater than 5 C and LPG cylinder is less than 25 full Replace LPG cylind...

Отзывы: