background image

2 of 11 

 

INDEX 

Specification   

Page 2 

Gas Firepit Safety Warnings 

Page 3 

Expanded View 

Page 5 

Installation   

Page 6 

Operating Instructions 

Page 7 

Leakage Testing 

Page 8 

Gas Requirements 

Page 8 

LPG Cylinder 

Page 9 

Important Safety Rules 

Page 9 

Maintenance and Cleaning 

Page 9 

Storage (after use) 

Page 10 

Troubleshooting 

Page 11 

 
 

SPECIFICATION 

Product Name 

Gas Firepit “STELLAR” 

Model 

dobar 35441E 

Pin code   

2531CS-0150 

Nominal heat input   

9.3 kW (Hi) 

Gas consumption 

733 g/h (Hi) 

Gas category 

I

3B/P(50) 

Gas Type 

Propane, butane and their mixtures 

Gas pressure 

50 mbar 

Injector diameter 

Ø 1.33 mm x 1 pcs 

Destination countries   

AT, DE, SK, CH, LU 

Gas regulator 

Certified regulator according to EN 16129 (flow rate: max. 1.5kg/h) 

Gas hose 

Certified gas hose according to applicable EN-standard (max1.5m) 

Gas cylinder   

Standard gas cylinder (recommend to use 4.5kg ~ 15kg) 

Appliance dimension   

500*500*500 mm 

Mass appliance 

16 kg 

 

 

This  appliance  was  designed  and  made  in  accordance  with  EN509  and  EN437  plus  subsequent 
amendments (gas standards). 
This  appliance  complies  with  the  prescriptions  of  Gas  Appliance  Directive  2009/  142/EC  and  Gas 
Appliance Regulation 2016/426/EU. 
The 

EC Declaration of Conformity from the importeur can be requested. State of information: 2018 

 

This symbol is stick on in the higher part of the appliance (do not remove it).   

 

 
 
 
 
 

 

Attention: 

Surface very hot! 

Do not touch!!!! 

Содержание 35441E

Страница 1: ...se Warning Accessible parts may be very hot keep young children away This appliance must be installed in accordance with the rules in force and used only in a sufficiently ventilated space Consult ins...

Страница 2: ...3 mm x 1 pcs Destination countries AT DE SK CH LU Gas regulator Certified regulator according to EN 16129 flow rate max 1 5kg h Gas hose Certified gas hose according to applicable EN standard max1 5m...

Страница 3: ...y your self Never use this appliance until all connections have been leakage tested Never put it into operation if any leakage is detected check leakage all the time by soapy foam never using a flame...

Страница 4: ...ay away to avoid burns or clothing ignition If fire should go out turn gas supply in OFF position full disk and wait for 2 minutes before attempting to relight Children should be carefully supervised...

Страница 5: ...5 of 11 EXPANDED VIEW...

Страница 6: ...re supplied with this appliance and must be used according to National Rules in force You need to purchase one gas regulator and one gas cylinder The gas regulator has to be set according to specific...

Страница 7: ...aximum position big flame stop pushing ignition button star and keep the control knob pressed but not over 20 seconds to heat the thermocouple FSD then release it first ignition take generally more ti...

Страница 8: ...ing to EN 549 Class B2 or material used to guarantee tightness according to EN 751 1 Class I GAS REQUIREMENTS Use only the type of gas and the type of LPG cylinder specified by the manufacturer Applia...

Страница 9: ...inimum clearance is 1 m from combustible materials and or any wall side left right or back any ceiling is forbidden Appliance is not fitted with any guard it is recommended to use one for the protecti...

Страница 10: ...embling battery Please contact the Manufacturer or dealer for information regarding replacement hoses thermocouples igniters lava rocks etc Attention Never use unauthorized parts or component for this...

Страница 11: ...ressure Replace LPG cylinder with a new one Burner flame is low Note Do not operate appliance below 5 C Outdoor temperature is greater than 5 C and LPG cylinder is less than 25 full Replace LPG cylind...

Отзывы: