I
NSTRUCTION
&
P
ARTS
M
ANUAL
Pag.
17
Edition A
The operator must be equipped with personal protection instruments, like gloves and safety glasses.
5.9.
C
OMMAND MODES
,
STOP
,
EMERGENCY STOP AND OUT OF SERVICE
.
5.9.1 Command modes
The saw can be controlled in two different ways, turning or pressing a selector switch or a push-button (different ways for
different models). The switch enable a relay which insert the manual mode.
9
Automatic mode ; the switch is on the automatic mode. All automatic commands are enable.
9
Manual mode, the switch is on the manual mode. All the commands are switched to the control panel push-button
and switches.
5.9.1.1. Stop
The saw stops when the cutting cycle is over.
5.9.1.2. Emergency stop
The emergency stop stops the machine removing tension from the control circuit.
5.9.1.3. Out of service
The saw can be turned out of service removing tension from the control circuit, switching off the main disconnect switch
located on the front face of the enclosure. A signal saying “Out of service” must be placed on the machine, and it is opera-
tor’s duty to verify that the machine cannot generate danger situations.
5.9.1.4. Safety precautions
The machine cannot generate danger situation when it is completely without electric or hydraulic power.
Concerning the electrical power, the machine must be completely disconnected from electrical sources, turning of the elec-
trical socket on the building electrical panel. The machine cannot be considered completely safe if the only main discon-
nect switch of the machine is turned off.