Dnake E416 Скачать руководство пользователя страница 25

21 

 

 

Quick Call & URL:  URL of the concierge button; 

RSTP Feed:  The video source for Indoor Monitor when call 

another Indoor Monitor. 

Local Relay Delay:  The length of unlock delay time (1-9s);  

Local Relay Type:  Type of local relay (Open Door is for lock/Chime 

Bell is for doorbell); 

Unlock Button 1-3:  Enable or disable relays for unlock buttons; 

Name:  Customize name for unlock button; 

Type:   Type 1-3: 3 types of unlock way are optional 

(Local Relay/DTMF/HTTP) 

HTTP

——

the format is http://192.168.1.63/cgi- 

bin/ext/control.cgi?op=unlock;  

IP here is an example of Door Station's IP; 

DTMF

——

Dual-tone multi-frequency signaling, 

Relay1: #, Relay2:0, relay3: *; 

Install Third-party App:  Install 3rd-party apps on Indoor Monitor. Click 

Choose File to select apk file and install. 

 

6.  Webkit 

The webkit column is designed for advertising.

 

 

Advertising:  Enable to display advertisements when Indoor 

Monitor is in the screensaver; 

Url:  The URL of advertisement; 

 

7.  Others 

The others column is designed for rebooting the device.

 

Содержание E416

Страница 1: ...User Manual DNAKE E416...

Страница 2: ......

Страница 3: ...only for reference If there is any difference please take the actual product as the standard The product and batteries must be handled separately from household waste When the product reaches the end...

Страница 4: ...ODUCT FEATURE 1 TECHNICAL PARAMETER 1 PACKAGE CONTENT 2 OVERVIEW 3 BASIC OPERATION 4 DEVICE SETTING 11 WEB SETTING 17 SYSTEM DIAGRAM 24 DEVICE WIRING 25 INSTALLATION 27 TROUBLESHOOTING 29 SAFETY INSTR...

Страница 5: ...rt monitoring 16 IP cameras TECHNICAL PARAMETER System Android 10 RAM 1 GB ROM 8 GB Front Panel Plastic Power Supply PoE 802 3af or DC 12V 2A Standby Power 3 W Rated Power 10 W Wi Fi IEEE802 11 b g n...

Страница 6: ...2 PACKAGE CONTENT MODEL E416 E416 Wiring Cover PM4 20 2 pcs Diode 3 pcs Quick Start Guide Desktop Stand Optional...

Страница 7: ...3 OVERVIEW...

Страница 8: ...1 Riser 1111 Dial button 2 Monitor Click Monitor icon on Indoor Monitor s homepage to monitor Door Station You can unlock by clicking door icon or switch to monitor other devices by clicking left and...

Страница 9: ...in 5 Quad Splitter On the 2nd homepage click Quad Splitter Click any screen of IPC to make it full screen Click left or right arrow to check other pages Up to 16 IPC can be added 6 Phonebook Slide fro...

Страница 10: ...ial button to call 7 QR Code Click QR Code and scan by Smart Life app to add this Indoor Monitor to your phone Only when the license is filled in Internet connected Indoor Monitor QR code will be avai...

Страница 11: ...ck OFF to disable scene Within Activation Time click the OFF icon and enter password to terminate the alarm sending to Master Station the default password is 1234 8 2 Zone Type Normal Only when the se...

Страница 12: ...connection to NC or NO the alarm can be triggered normally NO normally open NC normally closed BELL in BELL mode Master Station will not receive any alarm Indoor Monitor is regarded as a doorbell rece...

Страница 13: ...security password of the Device Confirm Confirm security password of the Device 9 Concierge Press the Concierge icon to call Master Station 10 Elevator Press the Elevator icon to call control elevator...

Страница 14: ...No Sync the same as other Indoor Monitors and Device number should be different The Device number can be from 0 to 9 But you must have one Indoor Monitor s Device number is 0 and keep it online becaus...

Страница 15: ...he same LAN Go to Settings to configure the device 1 Display Brightness level Screen brightness adjustment Sleep Screen sleep time 15s 30s 1min 2mins 5mins 20mins 30mins 2 Sounds Auto Answer Pick up a...

Страница 16: ...e to synchronize computer time Time Zone A region that observes a uniform standard time 12H 24H The format of time NTP Network Time Protocol NTP is a protocol used to synchronize computer time 4 Langu...

Страница 17: ...op Click pen icon to edit devices 6 Version Firmware Firmware version of the device IP Current IP address of the device Wi Fi IP Current Wi Fi IP address of the device MAC MAC address of the device 7...

Страница 18: ...Configure Static IP address to manually distributing network configuration parameters Mask Subnet mask Gateway A component that is part of two networks which use different protocols DNS Domain Name Se...

Страница 19: ...Password Password you set for this device s CMS registration 10 More SIP SIP enable Enable to use SIP Proxy SIP Server Host of SIP the default port is 5060 Realm Realm of SIP the default port is 5060...

Страница 20: ...16 12 More Apps Apps 3rd party apps can be managed here 13 More Reset Reset Reset to factory settings...

Страница 21: ...can configure the device To get the IP address you can search by DNAKE Remote Upgrade Tool installed in the same LAN with the devices 1 Main When you first log in to the web interface you can find ba...

Страница 22: ...erver of the device Eth wifi Enable to activate the network port and Wi Fi of the device to work simultaneously 3 RoomNo Numbers here are basic settings for making a call to Indoor Monitor For Door St...

Страница 23: ...e room Device Number of the device Unit range 1 9 Sync A number used to synchronize to other Indoor Monitors Server Server address of CMS Password Password you set for this device s CMS registration 4...

Страница 24: ...s 5060 Username Username of SIP Password Password of SIP Timeout The call will be ended automatically after a period of time 120s 300s 600s 1200s 1800s Voice Multicast Used to broadcast 5 Advanced Ex...

Страница 25: ...types of unlock way are optional Local Relay DTMF HTTP HTTP the format is http 192 168 1 63 cgi bin ext control cgi op unlock IP here is an example of Door Station s IP DTMF Dual tone multi frequency...

Страница 26: ...22 Reboot Reboot the device 8 License The license column will be hidden in the near future 9 System The system column is designed for packet capture and logs capture...

Страница 27: ...23 Tcpdump Capturing packets can help developers reproduce positioning problems Logcat Device logs 10 Logout The logout column is designed for logout...

Страница 28: ...24 SYSTEM DIAGRAM...

Страница 29: ...2 3at PoE and its output power not less than 30W and its output voltage not be less than 50V 2 Power The power interface of Indoor Monitor connects to 12V DC power 3 Relay Output 4 RS485 Enable to con...

Страница 30: ...connecting to an inductive load device such as a relay or electromagnetic lock you are recommended to use a diode 1A 400V included in the accessories in anti parallel with the load device to absorb i...

Страница 31: ...27 INSTALLATION Surface Mounting 86 Mounting Box Product size 195 130 14 5 mm...

Страница 32: ...28 Desktop Mounting Product size 195 130 14 5 mm Tips The camera should be 1450 1550mm above the ground The camera at this height can capture human face perfectly...

Страница 33: ...annot be played normally Check whether the system supports the file format Please refer to the multimedia setting for details No response when clicking Indoor Monitor display screen Press Unlock butto...

Страница 34: ...e the impact Do not use the power supply without the manufacturer s approval Do not have the liquids such as water go into the device Clean Device Surface Clean the device surfaces with soft cloth dip...

Страница 35: ...EASY SMART INTERCOM SOLUTIONS V1 2...

Отзывы: