Adjust Servo control signal
In according to the used Servo it can be advantageous to adapt the impulse-times.
The minimum time for the left position can be set within the range 0,1-2,5ms. The
maximum time for the right position must be bigger than the minimum time and can
be maximum 2,54ms.
Please proceed as following for the settings:
-
Turn on the DMX-Servo-Control
-
Set DIP-Switch 9 and 10 on OFF
-
Set DIP-Switch 10 on ON
-
Set via the DIP-Switched 1-8 the Minimum time
-
Set DIP-Switch 9 on ON
-
Set via the DIP-Switched 1-8 the Maximum time
-
Set DIP-Switch 10 on OFF
-
The LED lights up 4x as confirmation that the settings are stored
-
Set via DIP-Switches 1-9 the DMX-Starting address
The time-setting takes place with the DMX-Addressing via the DIP-Switches in 10µs
steps. Thereby the set value with 0,01ms is multiplied, so for example a value of 100
results in a value of 1ms.
1,00ms
= 100 x 0,01ms
2,52ms
= 252 x 0,01ms
1,01ms
= 101 x 0,01ms
2,53ms
= 253 x 0,01ms
1,02ms
= 102 x 0,01ms
2,54ms
= 254 x 0,01ms
The RDM parameters LEFT_ADJUST and RIGHT_ADJUST can also be used
to set the pulse time.