ArtNet Multi PixxControl

 

 

Pixel-assignment 

 

8-Bit Control 

 
The 

ArtNet Multi PixxControl

 controls up to 2720 RGB-Pixel. Therefore 16 ArtNet 

ports will be used per 170 RGB-Pixel. At the 8-bit control one channel ist used for R, 
G and B. This means each port (universe) can control 170 RGB pixels. 
 
The single pixel are assigned to the ArtNet-Ports as follows: 
 
 

1

2

3

170

ArtNet Node A - Port 1

K

a

n

a

l1

K

a

n

a

5

1

0

K

a

n

a

l2

K

a

n

a

l3

K

a

n

a

l4

K

a

n

a

l5

K

a

n

a

l6

K

a

n

a

l7

K

a

n

a

l8

K

a

n

a

l9

K

a

n

a

l5

0

8

K

a

n

a

l5

0

9

Pixel:

171

172

173

340

ArtNet Node A - Port 2

K

a

n

a

l1

K

a

n

a

5

1

0

K

a

n

a

l2

K

a

n

a

l3

K

a

n

a

l4

K

a

n

a

l5

K

a

n

a

l6

K

a

n

a

l7

K

a

n

a

l8

K

a

n

a

l9

K

a

n

a

l5

0

8

K

a

n

a

l5

0

9

2551 2552 2553

2720

ArtNet Node D - Port 4

K

a

n

a

l1

K

a

n

a

5

1

0

K

a

n

a

l2

K

a

n

a

l3

K

a

n

a

l4

K

a

n

a

l5

K

a

n

a

l6

K

a

n

a

l7

K

a

n

a

l8

K

a

n

a

l9

K

a

n

a

l5

0

8

K

a

n

a

l5

0

9

 

 
 
 
 

ArtNet-Port  Pixel 

Node A1 

1-170 

Node A2 

171-340 

Node A3 

341-510 

Node A4 

511-680 

Node B1 

681-850 

Node B2 

851-1020 

Node B3 

1021-1190 

Node B4 

1191-1360 

Node C1 

1361-1530 

Node C2 

1531-1700 

Node C3 

1701-1870 

Node C4 

1871-2040 

Node D1 

2041-2210 

Node D2 

2211-2380 

Node D3 

2381-2550 

Node D4 

2551-2720 

 

Содержание ArtNet Multi PixxControl

Страница 1: ...ArtNet Multi PixxControl User Manual Art Net Designed by and Copyright Artistic Licence Holdings Ltd...

Страница 2: ...Lighting Control Solutions for a simple and optimal controlling via ArtNet Technical Data Firmware Version 2 15 Power Supply 5V DC included in delivery Connections RJ45 Ethernet Art Net 4 pin Neutrik...

Страница 3: ...A TM1812 NC GND DATA TM1829 NC GND DATA WS2801 NC CLK GND DATA WS2811 NC GND DATA WS2812 B NC GND DATA LPD8803 NC CLK GND DATA Dyco LED NC CLK GND DATA UCS1903 NC GND DATA UCS9812 NC GND DATA APA 101...

Страница 4: ...ixxControl Kabel MagiarLED PixxControl Kabel Open End Connection exaples for stripes with 1 signal DATA Digital LED stripes with only 1 control signals DATA and GND must be connected e g for the WS281...

Страница 5: ...red separately For a better distinction you can give every node a arbitrary name The Short name is limited to 18 marks and the Long name is limited to 64 marks The subnet mask is to leave in accordanc...

Страница 6: ...ArtNet Multi PixxControl 6 Call up the IP 2 0 0 10 in the addressing list of the web browser to get the following configuration site...

Страница 7: ...ArtNet Multi PixxControl 7 Extension Setup In the Extension Setup the ArtNet parameters Net SubNet and Port can be adjusted for every node...

Страница 8: ...UCS1903 1360 19 9 APA 101 1360 78 42 LPD1886 8Bit 1360 50 27 LPD1886 12Bit 1360 36 20 LPD1886 12Bit SingleColor 1360 30 18 WS2811 1360 32 16 WS2812 WS2812B 1360 32 16 UCS9812 8Bit Ctrl 850 22 18 850Pi...

Страница 9: ...l4 Kanal5 Kanal6 Kanal7 Kanal8 Kanal9 Kanal508 Kanal509 Pixel 171 172 173 340 ArtNet Node A Port 2 Kanal1 Kanal 510 Kanal2 Kanal3 Kanal4 Kanal5 Kanal6 Kanal7 Kanal8 Kanal9 Kanal508 Kanal509 2551 2552...

Страница 10: ...Node A Port 1 Kanal1 Kanal 510 Kanal2 Kanal3 Kanal4 Kanal5 Kanal6 Kanal7 Kanal8 Kanal9 Kanal508 Kanal509 Pixel ArtNet Node A Port 2 Kanal1 Kanal2 Kanal3 Kanal4 Kanal5 Kanal6 H H ArtNet Node C Port 2...

Страница 11: ...0 0 0 0 1 0 15 2 0 0 18 2 0 0 21 255 0 0 0 0 2 0 15 IP Netmask 2 0 0 1 255 0 0 0 For a unique pixel mapping it is necessary to configure each ArtNet Multi PixxControl Based on this configuration on t...

Страница 12: ...Multi PixxControl can be skipped the Nodes unused ports IP Netmask Net SubNet Port PC mit Steuersoftware Ethernet Switch Pixel 1 Pixel 1020 ArtNet Multi PixxControl ArtNet Multi PixxControl ArtNet Mu...

Страница 13: ...w LED flashes Release button Push button again and hold Green and yellow LED flash ca 10 seconds alternately Meanwhile release button Now the reset will be executed and the LEDs lights up 3 times simu...

Страница 14: ...e Click Firmware Update Select and confirm Firmware data bin Please wait until the update has finished If an error occurs you can begin from the start anytime Alternatively you can activate the firmwa...

Страница 15: ...ArtNet Multi PixxControl 15 Equipment MagiarLED III flex Stripe MagiarLED III flex Screen Multi PixxControl Connection cable...

Страница 16: ...evice paperwork This work can only be done by qualified personnel which read the full device paperwork and understand it Operating risk The Change or the operation under special conditions of the inst...

Страница 17: ...nformation contained in this manual was arranged with largest care and after best knowledge Nevertheless errors are to be excluded not completely For this reason I see myself compelled to point out th...